PEL: Add low temperature message reg entries
Add entries for temperature critical/warning low and critical/warning
low clear to the message registry.
The sensor-monitor application creates these errors when sensors that
have these low thresholds defined trip their alarms.
Signed-off-by: Matt Spinler <spinler@us.ibm.com>
Change-Id: Ifb926d1ebeeed246e87565dd69c48a08db61e1dc
diff --git a/extensions/openpower-pels/registry/message_registry.json b/extensions/openpower-pels/registry/message_registry.json
index f26f4a6..f2c55f1 100644
--- a/extensions/openpower-pels/registry/message_registry.json
+++ b/extensions/openpower-pels/registry/message_registry.json
@@ -2803,6 +2803,94 @@
},
{
+ "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLow",
+ "Subsystem": "power",
+ "ComponentID": "0x2800",
+ "Severity": "predictive",
+ "ActionFlags": ["service_action", "report"],
+
+ "SRC": {
+ "ReasonCode": "0x280E",
+ "Words6To9": {}
+ },
+
+ "Documentation": {
+ "Description": "A temperature sensor is under its low warning threshold.",
+ "Message": "A temperature sensor is under its low warning threshold.",
+ "Notes": [
+ "A temperature sensor crossed its low warning threshold value",
+ "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout."
+ ]
+ }
+ },
+
+ {
+ "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureWarningLowClear",
+ "Subsystem": "power",
+ "ComponentID": "0x2800",
+ "Severity": "non_error",
+ "ActionFlags": ["report"],
+ "EventType": "env_normal",
+
+ "SRC": {
+ "ReasonCode": "0x280F",
+ "Words6To9": {}
+ },
+
+ "Documentation": {
+ "Description": "A temperature sensor is above its low warning threshold.",
+ "Message": "A temperature sensor is above its low warning threshold.",
+ "Notes": [
+ "A temperature sensor crossed above its low warning threshold value."
+ ]
+ }
+ },
+
+ {
+ "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLow",
+ "Subsystem": "power",
+ "ComponentID": "0x2800",
+ "Severity": "predictive",
+ "ActionFlags": ["service_action", "report"],
+
+ "SRC": {
+ "ReasonCode": "0x2810",
+ "Words6To9": {}
+ },
+
+ "Documentation": {
+ "Description": "A temperature sensor is under its low critical threshold.",
+ "Message": "A temperature sensor is under its low critical threshold.",
+ "Notes": [
+ "A temperature sensor crossed its low critical threshold value",
+ "CALLOUT_INVENTORY_PATH will be passed in to add a FRU callout."
+ ]
+ }
+ },
+
+ {
+ "Name": "xyz.openbmc_project.Sensor.Threshold.Error.TemperatureCriticalLowClear",
+ "Subsystem": "power",
+ "ComponentID": "0x2800",
+ "Severity": "non_error",
+ "ActionFlags": ["report"],
+ "EventType": "env_normal",
+
+ "SRC": {
+ "ReasonCode": "0x2811",
+ "Words6To9": {}
+ },
+
+ "Documentation": {
+ "Description": "A temperature sensor is over its low critical threshold.",
+ "Message": "A temperature sensor is over its low critical threshold.",
+ "Notes": [
+ "A temperature sensor crossed above its critical threshold value"
+ ]
+ }
+ },
+
+ {
"Name": "com.ibm.VPD.Error.InvalidEepromPath",
"Subsystem": "cec_vpd",
"ComponentID": "0x4000",