PEL: Support creator supplied power fault flag
User can supply POWER_THERMAL_CRITICAL_FAULT=TRUE as part
of AdditionalData entry in the event log to set the power
fault bit in PEL
Tested: I ran unit test using docker. Also tested manually
by setting D-bus event log
Change-Id: Ifa03f091a7d1efcc67f181c2be1cc0a6240891e1
Signed-off-by: Vijay Lobo <vijaylobo@gmail.com>
diff --git a/extensions/openpower-pels/src.cpp b/extensions/openpower-pels/src.cpp
index 9257036..398cfaa 100644
--- a/extensions/openpower-pels/src.cpp
+++ b/extensions/openpower-pels/src.cpp
@@ -291,7 +291,10 @@
_version = srcVersion;
_flags = 0;
- if (regEntry.src.powerFault.value_or(false))
+
+ auto item = additionalData.getValue("POWER_THERMAL_CRITICAL_FAULT");
+ if ((regEntry.src.powerFault.value_or(false)) ||
+ (item.value_or("") == "TRUE"))
{
_flags |= powerFaultEvent;
}