tree: 772593389ba02b538be697274fd9643cdf2668f1 [path history] [tgz]
  1. configurations/
  2. test/
  3. main.cpp
  4. meson.build
  5. power_supply.cpp
  6. power_supply.hpp
  7. psu_manager.cpp
  8. psu_manager.hpp
  9. README.md
  10. util.cpp
  11. util.hpp
  12. util_base.hpp
phosphor-power-supply/README.md

OpenBMC power supply monitoring application.

Design document: https://github.com/openbmc/docs/blob/master/designs/psu-monitoring.md

Compile Options

To enable reading VPD data via PMBus commands to IBM common form factor power supplies (ibm-cffps), run meson with -Dibm-vpd=true.

JSON Configuration File

The JSON configuration file should contain:

PowerSupplies

An array of power supply properties.

Inventory

The D-Bus path used to check the power supply presence (Present) property.

Bus

An integer specifying the I2C bus that the PMBus power supply is on.

Address

A string representing the 16-bit I2C address of the PMBus power supply.

D-Bus System Configuration

Entity Manager provides information about the supported system configuration. The information is as follows:

Max Power Supplies

Integer that indicates the maximum number of power supplies that should be present. This is exposed via the MaxCount property.