| commit | 01bc612007c0248745a90f857fb9f72ba1586407 | [log] [tgz] |
|---|---|---|
| author | Matthew Barth <msbarth@us.ibm.com> | Wed Jan 29 11:35:04 2020 -0600 |
| committer | Matthew Barth <msbarth@us.ibm.com> | Mon Apr 27 16:09:02 2020 -0500 |
| tree | ba212dac1813c8deaa6a33a58ab8f6954d7cd963 | |
| parent | 0a0ef78a6e7f73a9fb876a775986cd2a6b3aad93 [diff] |
regs: Add/install monitor disable service
Create a service file to call a method within the phosphor-regulators
binary to disable monitoring of the regulators. Add this service file to
be installed within the systemd services
directory(`/lib/systemd/system/`).
Tested:
Disable of monitoring is called the earliest after a request to
poweroff
Signed-off-by: Matthew Barth <msbarth@us.ibm.com>
Change-Id: Idd8ad73c807faddc90a7d86fd09da0508d5461dd
Code for detecting and analyzing power faults on Witherspoon.
To build this package, do the following steps:
1. meson build
2. ninja -C build
To clean the repository again run `rm -rf build`.
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069//sys/bus/i2c/devices/3-0069/hwmon/hwmonX//sys/kernel/debug/pmbus/hwmonX//sys/kernel/debug/pmbus/hwmonX/cffps1/fruConfigs defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number attribute file from a directory specified by the above pmbus access type, and assign to PartNumber property in xyz.openbmc_project.Inventory.Decorator.Asset interface. "fruConfigs": [
{
"propertyName": "PartNumber",
"fileName": "part_number",
"interface": "xyz.openbmc_project.Inventory.Decorator.Asset"
}
]
psuDevices defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0's device is located in /sys/bus/i2c/devices/3-0069. "psuDevices": {
"/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069",
}