commit | 209690b532a9a2a6d5f64f3eabbaef5567c1c07d | [log] [tgz] |
---|---|---|
author | Jim Wright <jlwright@us.ibm.com> | Thu Nov 11 14:46:42 2021 -0600 |
committer | Jim Wright <jlwright@us.ibm.com> | Fri Nov 12 09:18:13 2021 -0600 |
tree | a217b2deca050d97223049bccbe28b1813423d63 | |
parent | 5d23d9d6805b33423fc9a839980deec8e42b7404 [diff] |
pseq: Add two second wait to power off In order to allow host and other BMC applications time to complete power off processing, add a two second wait before initiating power off to the power sequencer. Signed-off-by: Jim Wright <jlwright@us.ibm.com> Change-Id: I84517bfa776e0b321a47ae4986b5fc84b2682926
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }