commit | 32707088bf4eae60d0e16b4485768601a56d912c | [log] [tgz] |
---|---|---|
author | Matthew Barth <msbarth@us.ibm.com> | Mon Apr 13 13:59:04 2020 -0500 |
committer | Matthew Barth <msbarth@us.ibm.com> | Mon Apr 27 16:09:02 2020 -0500 |
tree | 0a6882ab48c406967b4e3a3fb66236f2c5307125 | |
parent | cd9ab087e6888796876df44e0fa998f1b5583877 [diff] |
regs: Regulators control program The regulators control program is used to control the mode in which the phosphor-regulators application should run in. This is done by doing dbus method calls into the phosphor-regulators service which changes the mode in which the application runs. Tested: Handles unsupported arguments and parameters Configure mode method called Enable monitoring mode method called Disable monitoring mode method called Signed-off-by: Matthew Barth <msbarth@us.ibm.com> Change-Id: Ia9c9b48469d39059d32518949faaa50c6a038236
Code for detecting and analyzing power faults on Witherspoon.
To build this package, do the following steps: 1. meson build 2. ninja -C build To clean the repository again run `rm -rf build`.
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }