commit | 18a8e4913257498f2271d4d1a7293329131df3e2 | [log] [tgz] |
---|---|---|
author | Bob King <Bob_King@wistron.com> | Thu Aug 20 17:17:16 2020 +0800 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Wed Oct 07 19:08:23 2020 +0000 |
tree | 2a329fcd78bd51538f3d7bfe75ab6e01fd5dc051 | |
parent | d692d6df0caba201e8f5a54f178b167070c397e1 [diff] |
regulators: Delete journal.cpp and mock_journal.cpp Delete the file journal.cpp, it is no longer needed. Delete the file mock_journal.cpp, it is no longer needed. Delete log() method in exception_utils.cpp, it is no longer needed. Signed-off-by: Bob King <Bob_King@wistron.com> Change-Id: Ifb9d3524f2b9c7f9b266e03ef52e1cba0a49c08d
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }