commit | b23e44332eb9e661c61adae11d2382ac50a0deb2 | [log] [tgz] |
---|---|---|
author | Adriana Kobylak <anoo@us.ibm.com> | Fri Apr 01 14:22:47 2022 +0000 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Fri Apr 01 16:15:37 2022 +0000 |
tree | 0c51ce8908dadc3448bad14c3b4415122273b7d6 | |
parent | fa2734d69e5382d720a84ad0c3278d561b610245 [diff] |
psu-ng: Skip power supply validation if none are present If no power supplies are present, it means the D-Bus objects have not been created yet, so skip the power supply validation (the validation may had been requested if the BMC rebooted while the host is on, so when the psu monitor starts up, the power state changes to On and the validation is requested). The validation will be requested again when the power supply D-Bus objects appear on D-Bus via the interfaces added callback. Tested: Rebooted the BMC at host runtime and verified no errors were created. Change-Id: Ifc59d1add04163afb46a589c0b8387bb3e8636cf Signed-off-by: Adriana Kobylak <anoo@us.ibm.com>
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }