Add 'long-tests' build option Add a new meson build option for handling long-running tests that should be excluded from CI. Meson enforces a timeout on testcases. If the testcase runs longer than the timeout value, the testcase is considered failed. The timeout value can be increased, but sometimes this is still insufficient. Testcases are run multiple times in CI, including within environments like valgrind that increase their run times. Very long running testcases should probably be excluded from CI runs rather than setting the timeout to an arbitrarily large value like 5 minutes. The 'long-tests' option defaults to disabled. Long-running tests will only be built and run if option is explicitly set to enabled. Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com> Change-Id: I012d15a74df70e2741fc44009294d2134787c8e0
Code for detecting and analyzing power faults on Witherspoon.
To build this package, do the following steps: 1. meson build 2. ninja -C build To clean the repository again run `rm -rf build`.
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }