commit | 4c67a3a007828c6d8123c46daa7d8d9a6a7466b3 | [log] [tgz] |
---|---|---|
author | Bob King <Bob_King@wistron.com> | Fri Feb 07 09:48:11 2020 +0800 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Fri Feb 21 12:27:53 2020 +0000 |
tree | 4ec0861fbc6a8e06c7a4d97a07cca0cf5171fa06 | |
parent | 99d8fa1a327373b4b5e5599e8a54ba81790ebd05 [diff] |
regulators: Add test cases for object 'configuration'. *Valid: test configuration with property rule_id and with no actions. *Valid: test configuration with property actions and with no rule_id. *Valid: comments not specified (optional property). *Valid: volts not specified (optional property). *Valid: configuration is property of a rail (vs. a device). *Invalid: comments property has wrong data type (not an array). *Invalid: test configuration with both property actions rule_id. *Invalid: test configuration with no rule_id and actions. *Invalid: test configuration with property volts wrong type. *Invalid: test configuration with property rule_id wrong type. *Invalid: test configuration with property actions wrong type. *Invalid: test configuration with property comments empty array. *Invalid: test configuration with property rule_id wrong format. *Invalid: test configuration with property actions empty array. Signed-off-by: Bob King <Bob_King@wistron.com> Change-Id: I9b1617c8eb1ac49c28089b4d0d85ae2bd55db80d
Code for detecting and analyzing power faults on Witherspoon.
To build this package, do the following steps: 1. meson build 2. ninja -C build To clean the repository again run `rm -rf build`.
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }