meson: disable long-tests by default Some of the automated tests in this repository take a long time to execute. The tests can sometimes time out during CI execution, causing a spurious failure. The meson `long-tests` option was added to avoid building and executing these tests during CI. A default value of this option was previously not defined, and the long tests were not run during CI. With recent changes to the meson version and meson.build file, these tests now run during CI. Set the default value of `long-tests` to disabled so they do not run during CI. Change-Id: I0f749c6b23ba97dffa15a2f809f880cee22872c1 Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson setup build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }