commit | 5e0346b34697dd7ae73111ee01428dc77efbbff0 | [log] [tgz] |
---|---|---|
author | Shawn McCarney <shawnmm@us.ibm.com> | Sat Oct 30 14:17:28 2021 -0500 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Mon Nov 01 19:02:25 2021 +0000 |
tree | 66c47be3f80faed1acf79b3df29c3311a7eeef59 | |
parent | 43d3263ca782c5894b7bd7fc48bdd1e956e574a6 [diff] |
regulators: Treat missing VPD keyword as empty Modify the VPD service to return an empty value if the specified VPD interface or keyword does not exist on the specified object path. This condition can occur when the system is operating normally and should not result in an error being logged. Tested: * Verified an empty value is returned if the VPD interface does not exist on the object path. * Verified an empty value is returned if the VPD keyword does not exist on the object path. * Verified correct value is returned if the VPD interface and keyword exist * See complete test plan at https://gist.github.com/smccarney/47b167706da49c7d78c4df818040ae72 Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com> Change-Id: Iaa7c24f4e00ee17506fd5acfd0145c733fa0d57b
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }