commit | fe78c1787f0046b4d8f57131963654c61e265bba | [log] [tgz] |
---|---|---|
author | Shawn McCarney <shawnmm@us.ibm.com> | Thu May 02 14:01:46 2024 -0500 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Thu May 02 14:41:01 2024 -0500 |
tree | 191bdacf86ce050d0ab8a125787c81804bf17f0a | |
parent | b89395b1ac9e91ac8a225f97ea94f20805db7e88 [diff] |
pseq: Refactor storage of debug data After a pgood fault is detected, debug data is collected from the power sequencer device. This data is stored in the additional data map used to log an error. The data is also written to the journal. Previously the debug data was stored by one virtual method declared in the StandardDevice class. This method stored all the debug data including the GPIO values. GPIO values are device-specific, so it is likely that subclasses will need to override this method to provide better formatting of the GPIO values. However, this means they will also be overriding other data storage performed by an ancestor class. This will likely lead to duplicated code. Refactor the storage of GPIO values to a separate virtual method. This will allow child classes to override just that functionality while inheriting and reusing other data storage from ancestor classes. Tested: * Verified automated tests ran successfully Change-Id: I654a6a6a2f5386e06f9e7887cecfbb74523b715f Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson setup build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }