commit | 3cf72398daff3a5d53c23373ae43112f436d1fe8 | [log] [tgz] |
---|---|---|
author | Shawn McCarney <shawnmm@us.ibm.com> | Thu May 22 14:06:04 2025 -0500 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Thu May 22 14:47:22 2025 -0500 |
tree | f4db992532e7fbe282da8bb474ee4ea3ae462a43 | |
parent | 31ae6ee8c0e17f121e5cb3e581361296d69fdf2d [diff] |
regulators: Initial Balcones config file Create an initial version of the voltage regulators JSON configuration file for Balcones systems. The file contains the minimum required structure plus some general rules that will likely be used in subsequent commits. This minimal file is enough for Balcones hardware bring-up. No voltage regulator configuration or monitoring will occur. The regulators will power on with their default register values. Tested: * Ran validation tool * Started Rainier 2S2U simulation session * Modified EntityManager data so that system appeared to be a Balcones * Tested that file was found and loaded successfully * Tested that chassis powered on successfully with no errors logged Change-Id: If6cd397bfeb956b726e7106e0bdf73cdcc9d2238 Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com>
This repository contains applications for configuring and monitoring devices that deliver power to the system.
Actively-maintained applications:
Legacy applications:
To build all applications in this repository:
meson setup build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:
/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/<driver>.<instance>/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface.
"fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
.
"psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }