sdbusplus: use shorter type aliases
The sdbusplus headers provide shortened aliases for many types.
Switch to using them to provide better code clarity and shorter
lines. Possible replacements are for:
* bus_t
* exception_t
* manager_t
* match_t
* message_t
* object_t
* slot_t
Signed-off-by: Patrick Williams <patrick@stwcx.xyz>
Change-Id: Ief05bd757cffb1453e058a719ee4b060861752e7
diff --git a/phosphor-power-sequencer/src/power_control.hpp b/phosphor-power-sequencer/src/power_control.hpp
index f659744..0e37f7e 100644
--- a/phosphor-power-sequencer/src/power_control.hpp
+++ b/phosphor-power-sequencer/src/power_control.hpp
@@ -18,7 +18,7 @@
namespace phosphor::power::sequencer
{
-using PowerObject = sdbusplus::server::object::object<PowerInterface>;
+using PowerObject = sdbusplus::server::object_t<PowerInterface>;
/**
* @class PowerControl
@@ -40,7 +40,7 @@
* @param bus D-Bus bus object
* @param event event object
*/
- PowerControl(sdbusplus::bus::bus& bus, const sdeventplus::Event& event);
+ PowerControl(sdbusplus::bus_t& bus, const sdeventplus::Event& event);
/** @copydoc PowerInterface::getPgood() */
int getPgood() const override;
@@ -55,7 +55,7 @@
* Callback function to handle interfacesAdded D-Bus signals
* @param msg Expanded sdbusplus message data
*/
- void interfacesAddedHandler(sdbusplus::message::message& msg);
+ void interfacesAddedHandler(sdbusplus::message_t& msg);
/** @copydoc PowerInterface::setPgoodTimeout() */
void setPgoodTimeout(int timeout) override;
@@ -70,7 +70,7 @@
/**
* The D-Bus bus object
*/
- sdbusplus::bus::bus& bus;
+ sdbusplus::bus_t& bus;
/**
* The power sequencer device to monitor.