commit | b9cf0d2b827b430b0ec24429ef6b9291a27f9ead | [log] [tgz] |
---|---|---|
author | George Liu <liuxiwei@inspur.com> | Tue Feb 28 10:32:42 2023 +0800 |
committer | George Liu <liuxiwei@inspur.com> | Thu Mar 09 09:01:08 2023 +0800 |
tree | c6eaa2222d2cb659f04196cb44daf22b446da31e | |
parent | 7f6921e5cd03b1eabeca6bedbdc8d6b28616634f [diff] |
tools: Fix some warnings by cppcheck Warning message: tools/i2c/i2c.hpp:30:9: performance: Variable 'busStr' is assigned in constructor body. Consider performing initialization in initialization list. [useInitializationList] busStr = "/dev/i2c-" + std::to_string(busId); ^ tools/power-utils/updater.cpp:213:18: style: Local variable 'devPath' shadows outer variable [shadowVariable] auto devPath = internal::getDevicePath(p); ^ tools/power-utils/updater.hpp:108:17: note: Shadowed declaration std::string devPath; ^ tools/power-utils/updater.cpp:213:18: note: Shadow variable auto devPath = internal::getDevicePath(p); ^ Tested: Verify that there are no such warnings in local CI. Signed-off-by: George Liu <liuxiwei@inspur.com> Change-Id: Ibc7536345ee40579256c398646ad00a05b686ab3
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }