commit | 8c232456650aa241976f9955701eb8f9922aeb19 | [log] [tgz] |
---|---|---|
author | Shawn McCarney <shawnmm@us.ibm.com> | Wed May 05 18:44:57 2021 -0500 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Mon May 10 16:15:46 2021 +0000 |
tree | 9c5ee1997572f6f281f7e0afb4b8850ec825cb22 | |
parent | b464b1545159e4ffa70d95950701b07be0d83897 [diff] |
regulators: Complete PMBusReadSensorAction class Complete implementation of the PMBusReadSensorAction class. Publish the sensor value on D-Bus using the Sensors service. Update gtests for this class to expect calls to the Sensors service. Fix some constructor parameter combinations that did not make sense, such as linear_16 format for non-voltage sensors. Also refactor the TestSDBusError exception class into a separate file. This allows it to be shared by multiple test cases. This class is a concrete implementation of the abstract sdbusplus::exception_t class used for D-Bus errors. Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com> Change-Id: I5a77616b2ae5b17224c296aeee88019512649589
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }