psu-ng: Validate configuration during power on

Create a function to validate the power supply configuration. Initially,
check that all power supplies are of the same model, and if not, create
an error log. This function will later add checks for total number of
power supplies and expected input voltage.

The validation is run on every power on. To cover the case where entity
manager has not run yet on power, trigger the validation on interfaces
added signal. Use a boolean flag to determine if the validation needs to
be run to avoid running it multiple times.

Tested: Verified the validation was successful on Rainier.
        Verified the error log data:
$ curl -k -H "X-Auth-Token: $token" \
  https://${bmc}/xyz/openbmc_project/logging/entry/2
{
  "data": {
    "AdditionalData": [
      "ACTUAL_MODEL=51E8",
      "CALLOUT_INVENTORY_PATH=/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply1",
      "EXPECTED_MODEL=51E9"
    ],
    "Associations": [],
    "Id": 2,
    "Message":
"xyz.openbmc_project.Power.PowerSupply.Error.NotSupported",
    "Path":
"/var/lib/phosphor-logging/extensions/pels/logs/2021040718580625_50000002",

Change-Id: Ib8dd23465bfd36b510197a88d41fc8419862f33b
Signed-off-by: Adriana Kobylak <anoo@us.ibm.com>
2 files changed
tree: fccb09e514c938d6b90807a1d9e51134b4e83ef9
  1. cold-redundancy/
  2. example/
  3. org/
  4. phosphor-power-sequencer/
  5. phosphor-power-supply/
  6. phosphor-regulators/
  7. power-sequencer/
  8. power-supply/
  9. services/
  10. test/
  11. tools/
  12. .clang-format
  13. .gitignore
  14. .shellcheck
  15. argument.hpp
  16. device.hpp
  17. device_monitor.hpp
  18. elog-errors.hpp
  19. file_descriptor.hpp
  20. gpio.cpp
  21. gpio.hpp
  22. LICENSE
  23. MAINTAINERS
  24. meson.build
  25. meson_options.txt
  26. names_values.hpp
  27. pmbus.cpp
  28. pmbus.hpp
  29. README.md
  30. types.hpp
  31. utility.cpp
  32. utility.hpp
README.md

Overview

This repository contains applications for configuring and monitoring devices that deliver power to the system.

  • cold-redundancy: Application that makes power supplies work in Cold Redundancy mode and rotates them at intervals.
  • phosphor-power-sequencer: Applications for configuring and monitoring power sequencer and related devices that support JSON-driven configuration.
  • phosphor-power-supply: Next generation power supply monitoring application.
  • phosphor-regulators: JSON-driven application that configures and monitors voltage regulators.
  • power-sequencer: A power sequencer monitoring application.
  • power-supply: Original power supply monitoring application.
  • tools/power-utils: Power supply utilities.

Build

To build all applications in this repository:

  meson build
  ninja -C build

To clean the repository and remove all build output:

  rm -rf build

You can specify meson options to customize the build process. For example, you can specify:

  • Which applications to build and install.
  • Application-specific configuration data, such as power sequencer type.
  • Whether to build tests.

Power Supply Monitor and Util JSON config

Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:

  • Where to access the pmbus attributes
  • Which attribute file in pmbus maps to which property and interface in D-Bus
  • Which kernel device directory is used on which PSU

There is an example psu.json to describe the necessary configurations.

  • inventoryPMBusAccessType defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:
    • Base: The base dir, e.g. /sys/bus/i2c/devices/3-0069/
    • Hwmon: The hwmon dir, e.g. /sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
    • Debug: The pmbus debug dir, e.g. /sys/kernel/debug/pmbus/hwmonX/
    • DeviceDebug: The device debug dir, e.g. '/sys/kernel/debug/./`
    • HwmonDeviceDebug: The hwmon device debug dir, e.g. /sys/kernel/debug/pmbus/hwmonX/cffps1/
  • fruConfigs defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number attribute file from a directory specified by the above pmbus access type, and assign to PartNumber property in xyz.openbmc_project.Inventory.Decorator.Asset interface.
      "fruConfigs": [
        {
          "propertyName": "PartNumber",
          "fileName": "part_number",
          "interface": "xyz.openbmc_project.Inventory.Decorator.Asset"
        }
      ]
    
  • psuDevices defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0's device is located in /sys/bus/i2c/devices/3-0069.
      "psuDevices": {
        "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069",
      }