commit | 9ef7a04305d7f21bca8d16a437d016c5b2950469 | [log] [tgz] |
---|---|---|
author | Faisal Awada <faisal@us.ibm.com> | Mon Aug 28 14:35:30 2023 +0000 |
committer | Faisal Awada <faisal@us.ibm.com> | Tue Aug 29 14:17:22 2023 +0000 |
tree | 3bfe9db86835fb05d05a4b5cee7b871519889ce3 | |
parent | 3b3ae8d0fc507cb0acf7f7da25d0402f25ea211d [diff] |
psu-ng: Fix race condition within PSU monitor. Modified validationTimeout to 30 seconds to give entity manager enough time to post PSU information. Previous timer was set to 10 seconds, it was going off before the PSU information available which caused PSUManager::analyze() method to log incorrect error "The power supply configuration is not supported" During analysis found out on some IBM systems took the entity manager 15 seconds after boot to post the PSU information. Test: * Tested on the system where the defect was consistent to reproduce * Tested IBM systems with supported PSUs. Change-Id: Ib96c5bd4dbe9b989e0e22763a70d746ff1578a23 Signed-off-by: Faisal Awada <faisal@us.ibm.com>
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }