| commit | abe4941845b64832b3e6945f9fc251ff68fd5edf | [log] [tgz] |
|---|---|---|
| author | Patrick Williams <patrick@stwcx.xyz> | Wed May 13 17:59:47 2020 -0500 |
| committer | Matt Spinler <spinler@us.ibm.com> | Mon May 18 14:28:57 2020 +0000 |
| tree | 8b68b72686dadd51a2f2c6cab5c23c290f3ef757 | |
| parent | 365d61c68825435d2afeb0c2e1ec007ccec5b603 [diff] |
sdbusplus: replace message::variant with std::variant Signed-off-by: Patrick Williams <patrick@stwcx.xyz> Change-Id: I96011a7be0c4577617fdbfcd95ffbc5a3177be49
Code for detecting and analyzing power faults on Witherspoon.
To build this package, do the following steps:
1. meson build
2. ninja -C build
To clean the repository again run `rm -rf build`.
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069//sys/bus/i2c/devices/3-0069/hwmon/hwmonX//sys/kernel/debug/pmbus/hwmonX//sys/kernel/debug/pmbus/hwmonX/cffps1/fruConfigs defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number attribute file from a directory specified by the above pmbus access type, and assign to PartNumber property in xyz.openbmc_project.Inventory.Decorator.Asset interface. "fruConfigs": [
{
"propertyName": "PartNumber",
"fileName": "part_number",
"interface": "xyz.openbmc_project.Inventory.Decorator.Asset"
}
]
psuDevices defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0's device is located in /sys/bus/i2c/devices/3-0069. "psuDevices": {
"/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069",
}