psu-ng: Power supply class updates for input history

Update the meson files to include the record_manager with the
phosphor-psu-monitor application.

Since we do not want to blindly enable input history for all power
supplies, base the enablement of the feature off of the driver name.
Change the PowerSupply class to require the driver name be passed in,
and pass that down via the PSUManager during the configuration
determination.

Add a server manager to the PSUManager to handle the INPUT HISTORY data
that will be under /org/open_power/sensors.

The INPUT_HISTORY command is handled via a sysfs file in binary format,
so add in a readBinary() base function to allow for mock testing.

Change-Id: Iea163892d5482e6f2dacacfbfa746f605af52ed5
Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
diff --git a/phosphor-power-supply/power_supply.cpp b/phosphor-power-supply/power_supply.cpp
index a7e3579..254c9c7 100644
--- a/phosphor-power-supply/power_supply.cpp
+++ b/phosphor-power-supply/power_supply.cpp
@@ -21,14 +21,21 @@
 // missing to present before running the bind command(s).
 constexpr auto bindDelay = 1000;
 
+// The number of INPUT_HISTORY records to keep on D-Bus.
+// Each record covers a 30-second span. That means two records are needed to
+// cover a minute of time. If we want one (1) hour of data, that would be 120
+// records.
+constexpr auto INPUT_HISTORY_MAX_RECORDS = 120;
+
 using namespace phosphor::logging;
 using namespace sdbusplus::xyz::openbmc_project::Common::Device::Error;
 
 PowerSupply::PowerSupply(sdbusplus::bus::bus& bus, const std::string& invpath,
                          std::uint8_t i2cbus, std::uint16_t i2caddr,
+                         const std::string& driver,
                          const std::string& gpioLineName) :
     bus(bus),
-    inventoryPath(invpath), bindPath("/sys/bus/i2c/drivers/ibm-cffps")
+    inventoryPath(invpath), bindPath("/sys/bus/i2c/drivers/" + driver)
 {
     if (inventoryPath.empty())
     {
@@ -84,6 +91,7 @@
 
         updatePresence();
         updateInventory();
+        setupInputHistory();
     }
 }
 
@@ -186,6 +194,7 @@
         }
 
         setPresence(bus, invpath, present, shortName);
+        setupInputHistory();
         updateInventory();
 
         // Need Functional to already be correct before calling this.
@@ -635,6 +644,11 @@
             }
 
             checkAvailability();
+
+            if (inputHistorySupported)
+            {
+                updateHistory();
+            }
         }
         catch (const ReadFailure& e)
         {
@@ -954,6 +968,86 @@
     }
 }
 
+void PowerSupply::setupInputHistory()
+{
+    if (bindPath.string().find("ibm-cffps") != std::string::npos)
+    {
+        // Do not enable input history for power supplies that are missing
+        if (present)
+        {
+            inputHistorySupported = true;
+            log<level::INFO>(
+                fmt::format("{} INPUT_HISTORY enabled", shortName).c_str());
+
+            std::string name{fmt::format("{}_input_power", shortName)};
+
+            historyObjectPath =
+                std::string{INPUT_HISTORY_SENSOR_ROOT} + '/' + name;
+
+            // If the power supply was present, we created the recordManager.
+            // If it then went missing, the recordManager is still there.
+            // If it then is reinserted, we should be able to use the
+            // recordManager that was allocated when it was initially present.
+            if (!recordManager)
+            {
+                recordManager = std::make_unique<history::RecordManager>(
+                    INPUT_HISTORY_MAX_RECORDS);
+            }
+
+            if (!average)
+            {
+                auto avgPath = historyObjectPath + '/' + history::Average::name;
+                average = std::make_unique<history::Average>(bus, avgPath);
+                log<level::DEBUG>(
+                    fmt::format("{} avgPath: {}", shortName, avgPath).c_str());
+            }
+            if (!maximum)
+            {
+                auto maxPath = historyObjectPath + '/' + history::Maximum::name;
+                maximum = std::make_unique<history::Maximum>(bus, maxPath);
+                log<level::DEBUG>(
+                    fmt::format("{} maxPath: {}", shortName, maxPath).c_str());
+            }
+
+            log<level::DEBUG>(fmt::format("{} historyObjectPath: {}", shortName,
+                                          historyObjectPath)
+                                  .c_str());
+        }
+    }
+    else
+    {
+        inputHistorySupported = false;
+    }
+}
+
+void PowerSupply::updateHistory()
+{
+    if (!recordManager)
+    {
+        // Not enabled
+        return;
+    }
+
+    if (!present)
+    {
+        // Cannot read when not present
+        return;
+    }
+
+    // Read just the most recent average/max record
+    auto data =
+        pmbusIntf->readBinary(INPUT_HISTORY, pmbus::Type::HwmonDeviceDebug,
+                              history::RecordManager::RAW_RECORD_SIZE);
+
+    // Update D-Bus only if something changed (a new record ID, or cleared out)
+    auto changed = recordManager->add(data);
+    if (changed)
+    {
+        average->values(std::move(recordManager->getAverageRecords()));
+        maximum->values(std::move(recordManager->getMaximumRecords()));
+    }
+}
+
 void PowerSupply::getInputVoltage(double& actualInputVoltage,