commit | c8cbeac2cada1032ba5f585956f818d671cbcc65 | [log] [tgz] |
---|---|---|
author | Shawn McCarney <shawnmm@us.ibm.com> | Fri Sep 10 15:42:56 2021 -0500 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Tue Sep 14 20:32:56 2021 +0000 |
tree | 41470f897dd1f73537084fff5df45db02204c606 | |
parent | 37af670e5a831df3093594ad66d4bac3bdc7285a [diff] |
regulators: Enable phase fault detection Modify the top level Manager class to perform phase fault detection every 15 seconds. If the chassis is powered on, phase faults will be detected in every regulator device in the system. Tested: * Tested where no phase fault found for a regulator. * Tested where an N phase fault found for a regulator. * Tested where an N+1 phase fault found for a regulator. * Tested where additional data was captured in phase fault error log. * Verified detection occurs every 15 seconds * Verified detection starts during power on after regulators are enabled. * Verified detection stops during power off before regulators are disabled. * Tested where no JSON configuration file was loaded. * Tested when application was restarted while system was powered on. Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com> Change-Id: I12ac16dfcf4f754e168ce1ff76795520f823349f
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }