commit | dc777fa24caeef02b824891bc700ba292b76cb77 | [log] [tgz] |
---|---|---|
author | Shawn McCarney <shawnmm@us.ibm.com> | Fri May 06 12:26:37 2022 -0500 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Sat May 07 10:48:23 2022 -0500 |
tree | c9ef38a23bd27acd60c1c9b66aa958af0444e4d8 | |
parent | 9666ddf6be93fca44411d495077dfedb5fd6bcdc [diff] |
regulators: Host reboot should not redo operations While powering on the host, a "warm reboot" of the host may occur one or more times. For example, the host boot process may update hardware in a way that requires a host reboot. During a "warm reboot" of the host, power to the chassis remains on. As a result, the following regulator operations should *not* be performed: * Configuring the regulators again. * Disabling and then re-enabling regulator monitoring for sensors and redundant phase faults. Modify several regulator systemd service files so that those regulator operations are not performed during a "warm reboot" of the host. Test Plan: * https://gist.github.com/smccarney/c2eea054b7439b84b55f4fb89f474413 Signed-off-by: Shawn McCarney <shawnmm@us.ibm.com> Change-Id: I5e4c97168f0f7cdd5d7d6bfed227c5769a86d5a8
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }