commit | d661809b171933cb679fd08394bfa124d41faf86 | [log] [tgz] |
---|---|---|
author | Bob King <Bob_King@wistron.com> | Tue Jan 21 11:31:46 2020 +0800 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Tue Feb 04 21:15:56 2020 +0000 |
tree | 818cf886d85cacdab51df8b10491c539b689474d | |
parent | cfc29d035dd7a8320ad13c9a8cc0172b933047b3 [diff] |
regulators: Add test cases for object 'pmbus_read_sensor'. Test cases for object 'pmbus_read_sensor' are: *Valid: test pmbus_read_sensor. *Valid: test pmbus_read_sensor with required properties. *Invalid: test pmbus_read_sensor with no type. *Invalid: test pmbus_read_sensor with no command. *Invalid: test pmbus_read_sensor with no format. *Invalid: test pmbus_read_sensor with property type wrong type. *Invalid: test pmbus_read_sensor with property command wrong type. *Invalid: test pmbus_read_sensor with property format wrong type. *Invalid: test pmbus_read_sensor with property exponent wrong type. *Invalid: test pmbus_read_sensor with property type wrong format. *Invalid: test pmbus_read_sensor with property command wrong format. *Invalid: test pmbus_read_sensor with property format wrong format. Signed-off-by: Bob King <Bob_King@wistron.com> Change-Id: Iaeee47b7edb360667bcb3028735bae2279082b81
Code for detecting and analyzing power faults on Witherspoon.
To build this package, do the following steps: 1. meson build 2. ninja -C build To clean the repository again run `rm -rf build`.
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }