commit | e1a075956a0d16fa1df92d64e1700eb688d7555e | [log] [tgz] |
---|---|---|
author | Jayanth Othayoth <ojayanth@gmail.com> | Fri Dec 06 11:54:09 2024 -0600 |
committer | Jayanth Othayoth <ojayanth@gmail.com> | Sat Dec 07 02:03:09 2024 -0600 |
tree | 2026c61a200a490150e639e986a98d492a06e945 | |
parent | b59b1fa2bb80ec968a706189b380a0cf6e4482a0 [diff] |
clang-tidy: Suppress unused private field warning Addressed warnings reported during clang-tidy enablement by marking unused private fields with the [[maybe_unused]] keyword in multiple instances. This temporarily suppresses the warnings until a permanent solution is implemented. ''' ./phosphor-regulators/src/manager.hpp:199:31: error: private field 'eventLoop' is not used [-Werror ./phosphor-regulators/src/dbus_sensor.hpp:316:23: error: private field 'bus' is not used [-Werror ''' Tested: Verified build and unit testing. Change-Id: I5c4424deaee8440c619f8d541ee6203c4d9d738b Signed-off-by: Jayanth Othayoth <ojayanth@gmail.com>
This repository contains applications for configuring and monitoring devices that deliver power to the system.
Actively-maintained applications:
Legacy applications:
To build all applications in this repository:
meson setup build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:
/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/<driver>.<instance>/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface.
"fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
.
"psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }