commit | f477eb760e73a887b4edaf7140649aa816529ff2 | [log] [tgz] |
---|---|---|
author | Brandon Wyman <bjwyman@gmail.com> | Thu Jul 28 16:30:54 2022 +0000 |
committer | Brandon Wyman <bjwyman@gmail.com> | Fri Jul 29 22:45:41 2022 +0000 |
tree | 32f243b98d6968e6692dca4ca121cc14b3298e7b | |
parent | 056935ca73fa6ecdc559afe53a0c79e5edeaa8cc [diff] |
psu-ng: Limit calling of missing PSU helper Only call updateMissingPSUs() if we have an interface added for the supported configuration data, or new power supply device information. Tested: Simulated Rainier 2S2U - Verify fewer "D-Bus property ... access failure exception" traces. - Verify proper operations during power on. - Run simulated input fault, and repair, verify errors. Rainier 2S2U - Apply patched binary. - Verify D-Bus traces - Poweron, verify lack of additional D-Bus traces. Change-Id: I37833138e862ed910c072aa76491b0a413c18782 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
This repository contains applications for configuring and monitoring devices that deliver power to the system.
To build all applications in this repository:
meson build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }