commit | fcc2a2fb58966f5367bc86be5b50720c209fb965 | [log] [tgz] |
---|---|---|
author | Bob King <Bob_King@wistron.com> | Fri Jan 31 11:29:45 2020 +0800 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Fri Feb 21 12:56:48 2020 +0000 |
tree | 3755df6469dafc6fee2ae1fe04c9545997f4adb8 | |
parent | e9260b5736da6eb5196f921e2565cb524ca462e6 [diff] |
regulators: Add test cases for object 'sensor_monitoring'. *Valid: test sensor_monitoring with only property rule id. *Valid: test sensor_monitoring with only property actions. *Invalid: test sensor_monitoring with both property rule_id and actions. *Invalid: test sensor_monitoring with no rule_id and actions. *Invalid: test sensor_monitoring with property comments wrong type. *Invalid: test sensor_monitoring with property rule_id wrong type. *Invalid: test sensor_monitoring with property actions wrong type. *Invalid: test sensor_monitoring with property rule_id wrong format. *Invalid: test sensor_monitoring with property comments empty array. *Invalid: test sensor_monitoring with property actions empty array. Signed-off-by: Bob King <Bob_King@wistron.com> Change-Id: I8892dbdfe3546dd983b2c7d7478c287f79e98cc9
Code for detecting and analyzing power faults on Witherspoon.
To build this package, do the following steps: 1. meson build 2. ninja -C build To clean the repository again run `rm -rf build`.
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface."fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
."psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }