commit | 1cd4248d4afa664b94411dd57e7e686f944dfafc | [log] [tgz] |
---|---|---|
author | Lei YU <mine260309@gmail.com> | Tue Jul 24 10:40:59 2018 +0800 |
committer | Lei YU <mine260309@gmail.com> | Wed Sep 12 10:45:04 2018 +0800 |
tree | b49f3d0aa6c319b263b1134e329cd4f4ee65d3e6 | |
parent | 89efe6ed27a9df5a8e761073bdadd3fdd3fa5875 [diff] |
Fix un-initialized time owner/mode in manager The timeOwner/Mode in Manager class has no init value, and it is initialized with the cached time owner/mode in file system. In most of time it is OK because there is cached time owner/mode. But if the BMC does a factory reset, the cached values are cleaned up, and in next reboot the timeOwner/Mode will not be initialized at all. The fix is to give default time owner/mode, so when BMC comes from factory reset it uses default time settings. Tested: Verify the timeOwner/Mode have correct init values after factory reset. Change-Id: Ib1a8fba4d758f33ed09a7afdc9ed684867fca1c5
phosphor-time-manager
is the time manager service that implements D-Bus interface xyz/openbmc_project/Time/EpochTime.interface.yaml
. The user can get or set the BMC's or HOST's time via this interface.
The service xyz.openbmc_project.Time.Manager
provides two objects on D-Bus:
where each object implements interface xyz.openbmc_project.Time.EpochTime
.
The user can directly get or set the property Elapsed
of the objects to get or set the time. For example on an authenticated session:
### With busctl on BMC busctl get-property xyz.openbmc_project.Time.Manager \ /xyz/openbmc_project/time/bmc xyz.openbmc_project.Time.EpochTime Elapsed ### With REST API on remote host curl -b cjar -k https://${BMC_IP}/xyz/openbmc_project/time/bmc
### With busctl on BMC busctl set-property xyz.openbmc_project.Time.Manager \ /xyz/openbmc_project/time/host xyz.openbmc_project.Time.EpochTime \ Elapsed t <value-in-microseconds> ### With REST API on remote host curl -b cjar -k -H "Content-Type: application/json" -X PUT \ -d '{"data": 1487304700000000}' \ https://${BMC_IP}/xyz/openbmc_project/time/host/attr/Elapsed
Getting BMC or HOST time is always allowed, but setting the time may not be allowed depending on the below two settings in the settings manager.
A summary of which cases the time can be set on BMC or HOST:
Mode | Owner | Set BMC Time | Set Host Time |
---|---|---|---|
NTP | BMC | Fail to set | Not allowed |
NTP | HOST | Not allowed | Not allowed |
NTP | SPLIT | Fail to set | OK |
NTP | BOTH | Fail to set | Not allowed |
MANUAL | BMC | OK | Not allowed |
MANUAL | HOST | Not allowed | OK |
MANUAL | SPLIT | OK | OK |
MANUAL | BOTH | OK | OK |
To set an NTP server:
### With busctl on BMC busctl set-property xyz.openbmc_project.Network \ /xyz/openbmc_project/network/eth0 \ xyz.openbmc_project.Network.EthernetInterface NTPServers \ as 1 "<ntp_server>" ### With REST API on remote host curl -c cjar -b cjar -k -H "Content-Type: application/json" -X PUT -d \ '{"data": ["<ntp_server>"] }' \ https://${BMC_IP}/xyz/openbmc_project/network/eth0/attr/NTPServers
To go into NTP mode
### With busctl on BMC busctl set-property xyz.openbmc_project.Settings \ /xyz/openbmc_project/time/sync_method xyz.openbmc_project.Time.Synchronization \ TimeSyncMethod s "xyz.openbmc_project.Time.Synchronization.Method.NTP" ### With REST API on remote host curl -c cjar -b cjar -k -H "Content-Type: application/json" -X PUT -d \ '{"data": "xyz.openbmc_project.Time.Synchronization.Method.NTP" }' \ https://${BMC_IP}/xyz/openbmc_project/time/sync_method/attr/TimeSyncMethod
To change owner
### With busctl on BMC busctl set-property xyz.openbmc_project.Settings \ /xyz/openbmc_project/time/owner xyz.openbmc_project.Time.Owner \ TimeOwner s xyz.openbmc_project.Time.Owner.Owners.BMC ### With REST API on remote host curl -c cjar -b cjar -k -H "Content-Type: application/json" -X PUT -d \ '{"data": "xyz.openbmc_project.Time.Owner.Owners.BMC" }' \ https://${BMC_IP}/xyz/openbmc_project/time/owner/attr/TimeOwner
When the host is on, the changes of the above time mode/owner are not applied but deferred. The changes of the mode/owner are saved to persistent storage.
When the host is off, the saved mode/owner are read from persistent storage and are applied.
Note: A user can set the time mode and owner in the settings daemon at any time, but the time manager applying them is governed by the above condition.