commit | 4e6081bc836783d9cdb96b3b8be7042521cb6e60 | [log] [tgz] |
---|---|---|
author | George Liu <liuxiwei@ieisystem.com> | Thu Sep 19 10:09:04 2024 +0800 |
committer | George Liu <liuxiwei@ieisystem.com> | Thu Sep 19 10:39:02 2024 +0800 |
tree | 0268cd4288265f4406f1a6e9827b2c88d3ce4f3d | |
parent | b4cea1b1004a067be3503c59454aa21e8b369250 [diff] |
Add func for sum value when sensor from DBus Add a function that calculates the sum of all values. Signed-off-by: George Liu <liuxiwei@ieisystem.com> Change-Id: I922aab1a034be5c17f8725298ead99b113da5b5f
phosphor-virtual-sensor reads the configuration file virtual_sensor_config.json
from one of three locations:
/var/lib/phosphor-virtual-sensor
/usr/share/phosphor-virtual-sensor
By default the repository will install a sample config into (3).
There are two types of data in this file.
See virtual_sensor_config.json
in this repository for an example. Sensors added this way can use any expression that is accepted by exprtk.
For example:
{ "Desc": { "Config": "D-Bus", "Type": "ModifiedMedian" } }
Sensors added this way can only use a set of restricted calculations. Currently the only type supported is modifiedMedian
.
The virtual sensor configuration information needs to be added into the relevant hardware configuration file in entity-manager. This method of adding a virtual sensor allows a recipe that builds for different hardware configurations to have different virtual sensors for each configuration.
The virtual sensor configuration in entity manager follows a different format to the JSON in virtual_sensor_config.json
(specified in entity-manager/schemas/VirtualSensor.json).