WebUI: Dynamically get accountService roles

Get the AccountService roles dynamically
by calling redfish/rest API's and use them
in user management webui.

Test:
Loaded web page and checked user management
page for appropriate roles fetched from dbus.

Change-Id: I4f51cb0a622a1be8b0bfec2b2fe3ecdee2538c6a
Signed-off-by: AppaRao Puli <apparao.puli@linux.intel.com>
2 files changed
tree: 03f722f3eb2687408f19e9aff15d48079d3fd96a
  1. app/
  2. .babelrc
  3. .clang-format
  4. .gitignore
  5. config.json
  6. format-code.sh
  7. karma.conf.js
  8. LICENSE
  9. MAINTAINERS
  10. package-lock.json
  11. package.json
  12. postcss.config.js
  13. README.md
  14. sonar-project.properties
  15. webpack.config.js
README.md

OpenBMC Web User Interface

The OpenBMC WebUI is a Web-based user interface for the OpenBMC firmware stack. The WebUI uses AngularJS. Features include:

  • View system overview data such as model information and serial number
  • View and manage event logs
  • View inventory data
  • View sensor data
  • Power On/Off server operations
  • Reboot BMC
  • Manage and update BMC and Host firmware
  • IPv4 network settings
  • SoL console

Requirements

nodejs (>= 4.2.6) npm (>= 5.6.0)

Note The default installation of your Linux distro may not come with the required versions above. See the following for more information on updating:

https://docs.npmjs.com/troubleshooting/try-the-latest-stable-version-of-node https://docs.npmjs.com/troubleshooting/try-the-latest-stable-version-of-npm

Installation

npm install

Note This must be run from within the phosphor-webui git repository.

Running locally

npm run-script server

This will start a server instance and begin listening for connections at http://localhost:8080. This development server provides live reloading on code changes. NOTE: Browsing to https://<BMC> and accepting the self-signed certificate might be required to prevent your browser from blocking traffic to the BMC.

Logging in

Enter the BMC Host or BMC IP address, username, and password. The default username and password are root/0penBmc.

Note that some OpenBMC implementations use bmcweb for its backend. For security reasons, bmcweb will need to be recompiled and loaded onto the target BMC Host before the above redirect command will work. The option to turn on within bmcweb is BMCWEB_INSECURE_DISABLE_XSS_PREVENTION.