diff --git a/bin/sensor_manager.py b/bin/sensor_manager.py
index 33feebf..2314a7f 100644
--- a/bin/sensor_manager.py
+++ b/bin/sensor_manager.py
@@ -1,7 +1,7 @@
#!/usr/bin/env python
import sys
-import gobject
+from gi.repository import GObject
import dbus
import dbus.service
import dbus.mainloop.glib
@@ -9,7 +9,7 @@
if (len(sys.argv) < 2):
print "Usage: sensor_manager.py [system name]"
exit(1)
-
+System = __import__(sys.argv[1])
import Openbmc
DBUS_NAME = 'org.openbmc.managers.Sensors'
@@ -19,66 +19,67 @@
def __init__(self,bus,name):
dbus.service.Object.__init__(self,bus,name)
bus.add_signal_receiver(self.UpdateSensor,
- dbus_interface = 'org.openbmc.SensorInteger',
- signal_name = 'Changed', path_keyword='path')
+ dbus_interface = 'org.freedesktop.DBus.Properties',
+ signal_name = 'PropertiesChanged', path_keyword='path')
bus.add_signal_receiver(self.NormalThreshold,
- dbus_interface = 'org.openbmc.SensorIntegerThreshold',
+ dbus_interface = 'org.openbmc.SensorThreshold',
signal_name = 'Normal', path_keyword='path')
bus.add_signal_receiver(self.WarningThreshold,
- dbus_interface = 'org.openbmc.SensorIntegerThreshold',
+ dbus_interface = 'org.openbmc.SensorThreshold',
signal_name = 'Warning', path_keyword='path')
bus.add_signal_receiver(self.CriticalThreshold,
- dbus_interface = 'org.openbmc.SensorIntegerThreshold',
+ dbus_interface = 'org.openbmc.SensorThreshold',
signal_name = 'Critical', path_keyword='path')
self.sensor_cache = {}
@dbus.service.method(DBUS_NAME,
- in_signature='s', out_signature='i')
+ in_signature='s', out_signature='v')
def getSensor(self,path):
val = None
if (self.sensor_cache.has_key(path) == True):
val = self.sensor_cache[path]['value']
return val
- def UpdateSensor(self,value, units, path = None):
- if (self.sensor_cache.has_key(path) == False):
- self.sensor_cache[path] = {}
- self.sensor_cache[path]['value'] = value
- self.sensor_cache[path]['units'] = units
+ def UpdateSensor(self,interface,prop_dict,props, path = None):
+ if (interface == "org.openbmc.SensorValue"):
+ self.initSensorEntry(path)
+ for p in prop_dict.keys():
+ self.sensor_cache[path][p] = prop_dict[p]
@dbus.service.signal(DBUS_NAME)
def CriticalThreshold(self, path = None):
print "Critical: "+path
- if (self.sensor_cache.has_key(path) == False):
- self.sensor_cache[path] = {}
+ self.initSensorEntry(path)
self.sensor_cache[path]['threshold'] = "CRITICAL"
-
@dbus.service.signal(DBUS_NAME)
def WarningThreshold(self, path = None):
- print "Warning: "+path
- if (self.sensor_cache.has_key(path) == False):
- self.sensor_cache[path] = {}
+ print "Warning:"+path
+ self.initSensorEntry(path)
self.sensor_cache[path]['threshold'] = "WARNING"
-
@dbus.service.signal(DBUS_NAME)
def NormalThreshold(self, path = None):
print "Normal: "+path
- if (self.sensor_cache.has_key(path) == False):
- self.sensor_cache[path] = {}
+ self.initSensorEntry(path)
self.sensor_cache[path]['threshold'] = "NORMAL"
+ def initSensorEntry(self,path):
+ if (self.sensor_cache.has_key(path) == False):
+ self.sensor_cache[path] = {}
+ obj = bus.get_object(Openbmc.object_to_bus_name(path),path)
+ intf = dbus.Interface(obj,'org.freedesktop.DBus.Properties')
+ self.sensor_cache[path]['units'] = intf.Get('org.openbmc.SensorValue','units')
+
-
-
+
if __name__ == '__main__':
dbus.mainloop.glib.DBusGMainLoop(set_as_default=True)
bus = dbus.SessionBus()
name = dbus.service.BusName(DBUS_NAME,bus)
obj = SensorManager(bus,OBJ_NAME)
- mainloop = gobject.MainLoop()
+ mainloop = GObject.MainLoop()
print "Running Sensor Manager"
mainloop.run()