Fixed Assembly table Identify LED switches

Identify LED should toggle on/off successfully

Rewrote the patch code to work with the Redfish schema

Set LocationIndicatorActive to true:
curl -k -H "X-Auth-Token: $token" -X PATCH -d '
{
  "Assemblies":[
    {"MemberId" : "0", "LocationIndicatorActive":true},
    {"MemberId": "1", "LocationIndicatorActive":true}
  ]
}'
https://${bmc}/redfish/v1/Chassis/chassis/Assembly

MemberId is required to reference which assembly LED to toggle

Signed-off-by: Kenneth Fullbright <kennyneedsmilky@gmail.com>
Change-Id: Id0a3cf4dc533f6a0205be9fd037b13f92647cc00
diff --git a/src/store/modules/HardwareStatus/AssemblyStore.js b/src/store/modules/HardwareStatus/AssemblyStore.js
index 56e5631..fe97a9c 100644
--- a/src/store/modules/HardwareStatus/AssemblyStore.js
+++ b/src/store/modules/HardwareStatus/AssemblyStore.js
@@ -46,8 +46,14 @@
     async updateIdentifyLedValue({ dispatch }, led) {
       const uri = led.uri;
       const updatedIdentifyLedValue = {
-        LocationIndicatorActive: led.identifyLed,
+        Assemblies: [
+          {
+            MemberId: led.memberId,
+            LocationIndicatorActive: led.identifyLed,
+          },
+        ],
       };
+
       return await api.patch(uri, updatedIdentifyLedValue).catch((error) => {
         dispatch('getAssemblyInfo');
         console.log('error', error);