meta-quanta: s6q: enable IPMI SEL
Add inventory yaml and enable SEL option to trigger an alarm.
Tested:
Using settable temperature of ExternalSensor to trigger UCT/LCT signel.The result is verified on S6Q board.
Signed-off-by: Joseph Fu <joseph.fu@quantatw.com>
Change-Id: I72f3cc553e78864524761e541bdd6f56469ce290
diff --git a/meta-quanta/meta-s6q/recipes-phosphor/configuration/s6q-yaml-config.bb b/meta-quanta/meta-s6q/recipes-phosphor/configuration/s6q-yaml-config.bb
index bc52099..590bde8 100644
--- a/meta-quanta/meta-s6q/recipes-phosphor/configuration/s6q-yaml-config.bb
+++ b/meta-quanta/meta-s6q/recipes-phosphor/configuration/s6q-yaml-config.bb
@@ -9,6 +9,7 @@
file://ipmi-fru.yaml \
file://ipmi-fru-properties.yaml \
file://ipmi-sensors.yaml \
+ file://ipmi-inventory-sensors.yaml \
"
S = "${WORKDIR}"
@@ -17,12 +18,14 @@
install -m 0644 -D ipmi-fru.yaml ${D}${datadir}/${BPN}/ipmi-fru-read.yaml
install -m 0644 -D ipmi-fru-properties.yaml ${D}${datadir}/${BPN}/ipmi-extra-properties.yaml
install -m 0644 -D ipmi-sensors.yaml ${D}${datadir}/${BPN}/ipmi-sensors.yaml
+ install -m 0644 -D ipmi-inventory-sensors.yaml ${D}${datadir}/${BPN}/ipmi-inventory-sensors.yaml
}
FILES:${PN}-dev = " \
${datadir}/${BPN}/ipmi-fru-read.yaml \
${datadir}/${BPN}/ipmi-extra-properties.yaml \
${datadir}/${BPN}/ipmi-sensors.yaml \
+ ${datadir}/${BPN}/ipmi-inventory-sensors.yaml \
"
ALLOW_EMPTY:${PN} = "1"