| OBMC_BMC_INSTANCES ?= "0" |
| OBMC_CHASSIS_INSTANCES ?= "0" |
| OBMC_CHECKSTOP_INSTANCES ?= "0" |
| OBMC_FAN_INSTANCES ?= "" |
| OBMC_HOST_INSTANCES ?= "0" |
| OBMC_POWER_BUTTON_INSTANCES ?= "0" |
| OBMC_POWER_INSTANCES ?= "0" |
| OBMC_RESET_BUTTON_INSTANCES ?= "0" |
| OBMC_WATCHDOG_INSTANCES ?= "0" |
| |
| # obmc-bmc-state-manager |
| # |
| # Provides an implementation of the xyz.openbmc_project.State.BMC |
| # interface. |
| VIRTUAL-RUNTIME_obmc-bmc-state-manager ?= "phosphor-state-manager-bmc" |
| |
| # obmc-chassis-state-manager |
| # |
| # Provides an implementation of the xyz.openbmc_project.State.Chassis |
| # interface. |
| VIRTUAL-RUNTIME_obmc-chassis-state-manager ?= "phosphor-state-manager-chassis" |
| |
| # obmc-host-state-manager |
| # |
| # Provides an implementation of the xyz.openbmc_project.State.Host |
| # interface. |
| VIRTUAL-RUNTIME_obmc-host-state-manager ?= "phosphor-state-manager-host" |
| |
| # obmc-discover-system-state |
| # |
| # Provides an implementation of phosphor-discover-system-state, which, if the |
| # host is powered off, will check the current power policy and, if necessary, |
| # power the host back on. |
| VIRTUAL-RUNTIME_obmc-discover-system-state ?= "phosphor-state-manager-discover" |
| |
| # obmc-fan-presence |
| # |
| # Provides implementations of fan presence detection |
| VIRTUAL-RUNTIME_obmc-fan-presence ?= "phosphor-fan-presence-tach" |
| |
| # obmc-fan-control |
| # |
| # Provides implementations of fan control |
| VIRTUAL-RUNTIME_obmc-fan-control ?= "phosphor-fan-control" |
| |
| # obmc-inventory-manager |
| # |
| # Provides an implementation of the xyz.openbmc_project.Inventory.Manager |
| # interface. |
| VIRTUAL-RUNTIME_obmc-inventory-manager ?= "phosphor-inventory-manager" |
| |
| # obmc-led-manager |
| # |
| # Provides an implementation of the xyz.openbmc_project.ledmanager interface. |
| VIRTUAL-RUNTIME_obmc-leds-manager ?= "phosphor-led-manager" |
| |
| # obmc-led-monitor |
| # |
| # Provides an implementation of the FRU fault monitor. |
| VIRTUAL-RUNTIME_obmc-led-monitor ?= "phosphor-led-manager-faultmonitor" |
| |
| # obmc-led-sysfs |
| # |
| # Provides an implementation of xyz.openbmc_project.Led.Physical for |
| # Linux kernel LED subsystem LEDs. |
| VIRTUAL-RUNTIME_obmc-leds-sysfs ?= "phosphor-led-sysfs" |
| |
| # obmc-bmc-download-mgr |
| # |
| # Provides an implementation of the xyz.openbmc_project.Common.TFTP |
| # interface. |
| VIRTUAL-RUNTIME_obmc-bmc-download-mgr ?= "phosphor-software-manager-download-mgr" |
| |
| # obmc-bmc-version |
| # |
| # Provides an implementation of the xyz.openbmc_project.Software.Version |
| # interface. |
| VIRTUAL-RUNTIME_obmc-bmc-version ?= "phosphor-software-manager-version" |
| |
| # obmc-bmc-updater |
| # |
| # Provides an implementation of the xyz.openbmc_project.Software.Activation |
| # interface. |
| VIRTUAL-RUNTIME_obmc-bmc-updater ?= "phosphor-software-manager-updater" |
| |
| # obmc-sensors-hwmon |
| # |
| # Provides an implementation of xyz.openbmc_project.Sensor.Value |
| # for hwmon sensors. |
| VIRTUAL-RUNTIME_obmc-sensors-hwmon ?= "phosphor-hwmon" |
| |
| # obmc-dump-manager |
| # Provide support for managing dump |
| VIRTUAL-RUNTIME_obmc-dump-manager ?= "phosphor-debug-collector-manager" |
| |
| # obmc-dump-monitor |
| # Provide support for monitoring BMC core dumps |
| VIRTUAL-RUNTIME_obmc-dump-monitor ?= "phosphor-debug-collector-monitor" |
| |
| # phosphor-hwmon-config |
| # |
| # The phosphor-hwmon package can have its configuration generated |
| # automatically if the MRW feature is enabled. |
| VIRTUAL-RUNTIME_phosphor-hwmon-config ?= "" |
| |
| # obmc-network-manager |
| # |
| # Provide support for managing network |
| VIRTUAL-RUNTIME_obmc-network-manager ?= "phosphor-network" |
| |
| # Configuration overrides for phosphor-ipmi-fru. |
| # |
| # The phosphor-ipmi-fru application is data-driven and requires an input |
| # mapping of how the host firmware reports inventory via IPMI and the mapping |
| # of that inventory metadata to DBus objects interfaces and properties. |
| |
| # The phosphor-ipmi-fru application is data-driven and requires an input |
| # mapping of how the host firmware reports inventory via IPMI. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-ipmi-fru build process. |
| PREFERRED_PROVIDER_virtual/phosphor-ipmi-fru-hostfw-config ?= "phosphor-ipmi-fru-hostfw-config-example-native" |
| |
| # The phosphor-ipmi-fru application is data-driven and requires an input |
| # mapping of IPMI inventory metadata to DBus objects interfaces and properties. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-ipmi-fru build process in the native sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-ipmi-fru-inventory ?= \ |
| "phosphor-ipmi-fru-inventory-example-native" |
| |
| PREFERRED_PROVIDER_virtual/phosphor-ipmi-fru-properties ?= \ |
| "phosphor-ipmi-fru-properties-native" |
| |
| PREFERRED_PROVIDER_virtual/phosphor-ipmi-fru-read-inventory ?= \ |
| "phosphor-ipmi-fru-read-inventory-example-native" |
| |
| # Configuration overrides for phosphor-host-ipmid. |
| # |
| # The phosphor-host-ipmid application is data-driven. |
| |
| # The phosphor-host-ipmid application is data-driven and requires an input |
| # mapping of IPMI inventory sensor metadata to DBus objects interfaces and properties. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-host-ipmid build process in the native sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-ipmi-sensor-inventory ?= \ |
| "phosphor-ipmi-sensor-inventory-native" |
| |
| # The phosphor-host-ipmid application is data-driven and requires an input |
| # mapping of inventory object path to the sensor number and sensor metadata. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-host-ipmid build process in the native sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-ipmi-inventory-sel ?= \ |
| "phosphor-ipmi-inventory-sel-native" |
| |
| # Various other overrides. |
| |
| # The phosphor-led-manager application is data-driven and requires an input |
| # yaml of LED group and members. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-led-manager build process in the native sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-led-manager-config-native ?= \ |
| "phosphor-led-manager-config-example-native" |
| |
| # The phosphor-logging application has a data driven plugin that adds FRU |
| # callout information to error logs, when applications generating error logs |
| # add the requisite callout metadata to the systemd journal. The plugin requires |
| # an input mapping of Linux sysfs devices to OpenBMC DBus objects. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-logging build process in the native sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-logging-callouts ?= \ |
| "phosphor-logging-callouts-example-native" |
| |
| # The phosphor-fan-presence application is data driven and requires an input |
| # YAML that maps fans to their tach sensors. This virtual is a recipe that |
| # provides that mapping by installing configuration files in the format and |
| # sysroot location expected by the phosphor-fan-presence build process in the |
| # sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-fan-presence-config ?= \ |
| "phosphor-fan-presence-config" |
| |
| # The phosphor-fan-control application is data driven and requires a YAML file |
| # to define the fans in the system. This virtual is a recipe that provides |
| # that definition by installing the YAML file in the format and sysroot |
| # location expected by the phosphor-fan-control build process in the sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-fan-control-fan-config ?= \ |
| "phosphor-fan-control-fan-config" |
| |
| # The phosphor-gpio-monitor application is data-driven and requires an input. |
| # The application then watches the passed in input event entry for the |
| # change in polarity for the value matching user input. Once the required |
| # condition is met, it calls into a systemd target file if one is mentioned |
| # in input. |
| PREFERRED_PROVIDER_virtual/obmc-gpio-monitor ?= "phosphor-gpio-monitor" |
| |
| # The phosphor-watchdog application is data-driven and requires an input. |
| # The application then starts a timer in disabled state. User of this timer |
| # needs to first enable and then use it. This also provides a way for changing |
| # the timeout if needed. |
| PREFERRED_PROVIDER_virtual/obmc-watchdog ?= "phosphor-watchdog" |
| |
| # obmc-user-mgmt |
| # |
| # Provides an implementation of xyz.openbmc_project.User.Manager catering |
| # to user management |
| VIRTUAL-RUNTIME_obmc-user-mgmt ?= "phosphor-user-manager" |
| |
| OBMC_DBUS_PATH_ROOT ?= "/xyz/openbmc_project" |
| OBMC_DBUS_IFACE_ROOT ?= "xyz.openbmc_project" |
| |
| # VIRTUAL-RUNTIME_phosphor-ipmi-providers are the set of shared library |
| # plugins for the host-ipmid application. By default the IPMI FRU plugin |
| # is enabled. Additionally the host-ipmid recipe uses |
| # VIRTUAL-RUNTIME_phosphor-ipmi-providers to compute a list of potential |
| # IPMI whitelist recipe dependencies. For example: |
| # |
| # VIRTUAL-RUNTIME_phosphor-ipmi-providers ?= "phosphor-ipmi-fru" |
| # |
| # Will add a build dependency to host-ipmid on the |
| # phosphor-ipmi-fru-whitelist-native recipe. |
| VIRTUAL-RUNTIME_phosphor-ipmi-providers ?= "phosphor-ipmi-fru" |
| |
| # Set security headers on builds |
| require conf/distro/include/security_flags.inc |
| |
| # Disable security on croserver. |
| # Remove if https://github.com/open-power/eCMD/pull/433 is ever merged |
| SECURITY_STRINGFORMAT:pn-croserver = "" |
| # obmc-libobmc-intf doesn't compile with security flags enabled |
| SECURITY_CFLAGS:pn-obmc-libobmc-intf = "" |
| |
| # remove when https://gerrit.openbmc-project.xyz/c/openbmc/pldm/+/39984 |
| # is merged and rev bumped |
| SECURITY_CFLAGS:pn-pldm = "" |
| |
| # We generally want to enable LTO with meson |
| EXTRA_OEMESON:append:class-target = " -Db_lto=true" |
| |
| # Set the root password to '0penBmc' |
| # Override this in your local.conf |
| inherit extrausers |
| |
| # This is the default password for the OpenBMC root user account (0penBmc) |
| # salted and hashed with SHA512 suitable for /etc/shadow or `usermod -p`. |
| DEFAULT_OPENBMC_PASSWORD = "'\$6\$UGMqyqdG\$GqTb3tXPFx9AJlzTw/8X5RoW2Z.100dT.acuk8AFJfNQYr.ZRL8itMIgLqsdq46RNHgiv78XayOSl.IbR4DFU.'" |
| |
| EXTRA_USERS_PARAMS:pn-obmc-phosphor-image = " \ |
| usermod -p ${DEFAULT_OPENBMC_PASSWORD} root; \ |
| " |