blob: b798c6ee033438c2c4c10b6dc0349f8b86d4cab6 [file] [log] [blame]
# UBI-specific configuration for the phosphor-manager-software package
PACKAGECONFIG:append = " ubifs_layout"
RDEPENDS:phosphor-software-manager-updater-ubi += " \
mtd-utils-ubifs \
"
# Add ubi-fs configs
EXTRA_OEMESON:append = " \
-Dactive-bmc-max-allowed=2 \
-Dmedia-dir='/media' \
"
SYSTEMD_SERVICE:phosphor-software-manager-updater-ubi += " \
obmc-flash-bmc-ubirw.service \
obmc-flash-bmc-ubiro@.service \
obmc-flash-bmc-ubirw-remove.service \
obmc-flash-bmc-ubiro-remove@.service \
obmc-flash-bmc-ubiremount.service \
obmc-flash-bmc-updateubootvars@.service \
obmc-flash-bmc-cleanup.service \
obmc-flash-bmc-mirroruboot.service \
"
# Name of the mtd device where the ubi volumes should be created
BMC_RW_MTD ??= "bmc"
BMC_RO_MTD ??= "bmc"
BMC_KERNEL_MTD ??= "bmc"
DISTROOVERRIDES .= ":flash-${FLASH_SIZE}"
BMC_RW_SIZE ??= "0x600000"
BMC_RW_SIZE:flash-131072 = "0x2000000"
SYSTEMD_SUBSTITUTIONS += "RW_MTD:${BMC_RW_MTD}:obmc-flash-bmc-ubirw.service"
SYSTEMD_SUBSTITUTIONS += "RO_MTD:${BMC_RO_MTD}:obmc-flash-bmc-ubiro@.service"
SYSTEMD_SUBSTITUTIONS += "KERNEL_MTD:${BMC_KERNEL_MTD}:obmc-flash-bmc-ubiro@.service"
SYSTEMD_SUBSTITUTIONS += "RW_SIZE:${BMC_RW_SIZE}:obmc-flash-bmc-ubirw.service"