Andrei Kartashevc27f31f2021-11-30 13:50:42 +03001bmc_booted:
2 # No LED required.
3
4# Status LED indication
5# Managed by callback-manager
6# NOTE: The green LED actually has different colors on the front and rear
7# panels. So, we decided not to use it.
8# See https://j.yadro.com/browse/BBMC-221 for details.
9status_ok:
10 platform_status_green:
11 Action: 'Off'
Alexander Hansen3d403522024-08-23 19:04:20 +020012 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030013 platform_status_red:
14 Action: 'Off'
Alexander Hansen3d403522024-08-23 19:04:20 +020015 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030016
17status_degraded:
18 platform_status_green:
19 Action: 'Off'
Alexander Hansen3d403522024-08-23 19:04:20 +020020 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030021 platform_status_red:
22 Action: 'Blink'
23 DutyOn: 25
24 Period: 2000
Alexander Hansen3d403522024-08-23 19:04:20 +020025 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030026
27status_non_critical:
28 platform_status_green:
29 Action: 'Off'
Alexander Hansen3d403522024-08-23 19:04:20 +020030 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030031 platform_status_red:
32 Action: 'Blink'
33 DutyOn: 50
34 Period: 1000
Alexander Hansen3d403522024-08-23 19:04:20 +020035 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030036
37status_critical:
38 platform_status_green:
39 Action: 'Off'
Alexander Hansen3d403522024-08-23 19:04:20 +020040 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030041 platform_status_red:
42 Action: 'On'
Alexander Hansen3d403522024-08-23 19:04:20 +020043 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030044
45enclosure_identify:
46 platform_indicator_blue:
47 Action: 'On'
Alexander Hansen3d403522024-08-23 19:04:20 +020048 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030049
50#
51# May be asserted through IPMI or RedFish.
52# We decided that it should be the same as enclosure_identify.
53enclosure_identify_blink:
54 platform_indicator_blue:
55 Action: 'On'
Alexander Hansen3d403522024-08-23 19:04:20 +020056 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030057
58#
59# Asserted while firmware is flashing
60firmware_flashing:
61 platform_indicator_blue:
62 Action: 'Blink'
Alexander Hansen3d403522024-08-23 19:04:20 +020063 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030064
65#
66# Power button indication
67# Managed by phosphor-dbus-monitor
68power_standby:
69 platform_power_green:
70 Action: 'On'
Alexander Hansen3d403522024-08-23 19:04:20 +020071 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030072 platform_power_red:
73 Action: 'On'
Alexander Hansen3d403522024-08-23 19:04:20 +020074 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030075
76power_sequence:
77 platform_power_green:
78 Action: 'Blink'
79 DutyOn: 50
80 Period: 1000
Alexander Hansen3d403522024-08-23 19:04:20 +020081 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030082 platform_power_red:
83 Action: 'Off'
Alexander Hansen3d403522024-08-23 19:04:20 +020084 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030085
86power_on:
87 platform_power_green:
88 Action: 'On'
Alexander Hansen3d403522024-08-23 19:04:20 +020089 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030090 platform_power_red:
91 Action: 'Off'
Alexander Hansen3d403522024-08-23 19:04:20 +020092 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030093
94power_failure:
95 platform_power_green:
96 Action: 'Off'
Alexander Hansen3d403522024-08-23 19:04:20 +020097 Priority: 'Blink'
Andrei Kartashevc27f31f2021-11-30 13:50:42 +030098 platform_power_red:
99 Action: 'On'
Alexander Hansen3d403522024-08-23 19:04:20 +0200100 Priority: 'Blink'