| { |
| "$ref": "#/definitions/SerialInterface", |
| "$schema": "http://redfish.dmtf.org/schemas/v1/redfish-schema.v1_3_0.json", |
| "copyright": "Copyright 2014-2017 Distributed Management Task Force, Inc. (DMTF). For the full DMTF copyright policy, see http://www.dmtf.org/about/policies/copyright", |
| "definitions": { |
| "Actions": { |
| "additionalProperties": false, |
| "description": "The available actions for this resource.", |
| "longDescription": "This type shall contain the available actions for this resource.", |
| "patternProperties": { |
| "^([a-zA-Z_][a-zA-Z0-9_]*)?@(odata|Redfish|Message|Privileges)\\.[a-zA-Z_][a-zA-Z0-9_.]+$": { |
| "description": "This property shall specify a valid odata or Redfish property.", |
| "type": [ |
| "array", |
| "boolean", |
| "number", |
| "null", |
| "object", |
| "string" |
| ] |
| } |
| }, |
| "properties": { |
| "Oem": { |
| "$ref": "#/definitions/OemActions" |
| } |
| }, |
| "type": "object" |
| }, |
| "BitRate": { |
| "enum": [ |
| "1200", |
| "2400", |
| "4800", |
| "9600", |
| "19200", |
| "38400", |
| "57600", |
| "115200", |
| "230400" |
| ], |
| "enumDescriptions": { |
| "115200": "A bit rate of 115200bps.", |
| "1200": "A bit rate of 1200bps.", |
| "19200": "A bit rate of 19200bps.", |
| "230400": "A bit rate of 230400bps.", |
| "2400": "A bit rate of 2400bps.", |
| "38400": "A bit rate of 38400bps.", |
| "4800": "A bit rate of 4800bps.", |
| "57600": "A bit rate of 57600bps.", |
| "9600": "A bit rate of 9600bps." |
| }, |
| "type": "string" |
| }, |
| "ConnectorType": { |
| "enum": [ |
| "RJ45", |
| "RJ11", |
| "DB9 Female", |
| "DB9 Male", |
| "DB25 Female", |
| "DB25 Male", |
| "USB", |
| "mUSB", |
| "uUSB" |
| ], |
| "enumDescriptions": { |
| "DB25 Female": "A DB25 Female connector.", |
| "DB25 Male": "A DB25 Male connector.", |
| "DB9 Female": "A DB9 Female connector.", |
| "DB9 Male": "A DB9 Male connector.", |
| "RJ11": "An RJ11 connector.", |
| "RJ45": "An RJ45 connector.", |
| "USB": "A USB connector.", |
| "mUSB": "A mUSB connector.", |
| "uUSB": "A uUSB connector." |
| }, |
| "type": "string" |
| }, |
| "DataBits": { |
| "enum": [ |
| "5", |
| "6", |
| "7", |
| "8" |
| ], |
| "enumDescriptions": { |
| "5": "5 bits of data following the start bit.", |
| "6": "6 bits of data following the start bit.", |
| "7": "7 bits of data following the start bit.", |
| "8": "8 bits of data following the start bit." |
| }, |
| "type": "string" |
| }, |
| "FlowControl": { |
| "enum": [ |
| "None", |
| "Software", |
| "Hardware" |
| ], |
| "enumDescriptions": { |
| "Hardware": "Out of band flow control imposed.", |
| "None": "No flow control imposed.", |
| "Software": "XON/XOFF in-band flow control imposed." |
| }, |
| "type": "string" |
| }, |
| "OemActions": { |
| "additionalProperties": true, |
| "description": "The available OEM specific actions for this resource.", |
| "longDescription": "This type shall contain any additional OEM actions for this resource.", |
| "patternProperties": { |
| "^([a-zA-Z_][a-zA-Z0-9_]*)?@(odata|Redfish|Message|Privileges)\\.[a-zA-Z_][a-zA-Z0-9_.]+$": { |
| "description": "This property shall specify a valid odata or Redfish property.", |
| "type": [ |
| "array", |
| "boolean", |
| "number", |
| "null", |
| "object", |
| "string" |
| ] |
| } |
| }, |
| "properties": {}, |
| "type": "object" |
| }, |
| "Parity": { |
| "enum": [ |
| "None", |
| "Even", |
| "Odd", |
| "Mark", |
| "Space" |
| ], |
| "enumDescriptions": { |
| "Even": "An even parity bit.", |
| "Mark": "A mark parity bit.", |
| "None": "No parity bit.", |
| "Odd": "An odd parity bit.", |
| "Space": "A space parity bit." |
| }, |
| "type": "string" |
| }, |
| "PinOut": { |
| "enum": [ |
| "Cisco", |
| "Cyclades", |
| "Digi" |
| ], |
| "enumDescriptions": { |
| "Cisco": "The Cisco pin configuration.", |
| "Cyclades": "The Cyclades pin configuration.", |
| "Digi": "The Digi pin configuration." |
| }, |
| "type": "string" |
| }, |
| "SerialInterface": { |
| "additionalProperties": false, |
| "description": "This schema defines an asynchronous serial interface resource.", |
| "longDescription": "This resource shall be used to represent serial resources as part of the Redfish specification.", |
| "patternProperties": { |
| "^([a-zA-Z_][a-zA-Z0-9_]*)?@(odata|Redfish|Message|Privileges)\\.[a-zA-Z_][a-zA-Z0-9_.]+$": { |
| "description": "This property shall specify a valid odata or Redfish property.", |
| "type": [ |
| "array", |
| "boolean", |
| "number", |
| "null", |
| "object", |
| "string" |
| ] |
| } |
| }, |
| "properties": { |
| "@odata.context": { |
| "$ref": "http://redfish.dmtf.org/schemas/v1/odata.v4_0_1.json#/definitions/context" |
| }, |
| "@odata.id": { |
| "$ref": "http://redfish.dmtf.org/schemas/v1/odata.v4_0_1.json#/definitions/id" |
| }, |
| "@odata.type": { |
| "$ref": "http://redfish.dmtf.org/schemas/v1/odata.v4_0_1.json#/definitions/type" |
| }, |
| "Actions": { |
| "$ref": "#/definitions/Actions", |
| "description": "The available actions for this resource.", |
| "longDescription": "The Actions property shall contain the available actions for this resource." |
| }, |
| "BitRate": { |
| "$ref": "#/definitions/BitRate", |
| "description": "The receive and transmit rate of data flow, typically in bits-per-second (bps), over the serial connection.", |
| "longDescription": "This property shall indicate the transmit and receive speed of the serial connection.", |
| "readonly": false |
| }, |
| "ConnectorType": { |
| "$ref": "#/definitions/ConnectorType", |
| "description": "The type of connector used for this interface.", |
| "longDescription": "This property shall indicate the type of phyiscal connector used for this serial connection.", |
| "readonly": true |
| }, |
| "DataBits": { |
| "$ref": "#/definitions/DataBits", |
| "description": "The number of data bits that will follow the start bit over the serial connection.", |
| "longDescription": "This property shall indicate number of data bits for the serial connection.", |
| "readonly": false |
| }, |
| "Description": { |
| "anyOf": [ |
| { |
| "$ref": "http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/Description" |
| }, |
| { |
| "type": "null" |
| } |
| ], |
| "readonly": true |
| }, |
| "FlowControl": { |
| "$ref": "#/definitions/FlowControl", |
| "description": "The type of flow control, if any, that will be imposed on the serial connection.", |
| "longDescription": "This property shall indicate the flow control mechanism for the serial connection.", |
| "readonly": false |
| }, |
| "Id": { |
| "$ref": "http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/Id", |
| "readonly": true |
| }, |
| "InterfaceEnabled": { |
| "description": "This indicates whether this interface is enabled.", |
| "longDescription": "The value of this property shall be a boolean indicating whether this interface is enabled.", |
| "readonly": false, |
| "type": [ |
| "boolean", |
| "null" |
| ] |
| }, |
| "Name": { |
| "$ref": "http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/Name", |
| "readonly": true |
| }, |
| "Oem": { |
| "$ref": "http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/Oem", |
| "description": "This is the manufacturer/provider specific extension moniker used to divide the Oem object into sections.", |
| "longDescription": "The value of this string shall be of the format for the reserved word *Oem*." |
| }, |
| "Parity": { |
| "$ref": "#/definitions/Parity", |
| "description": "The type of parity used by the sender and receiver in order to detect errors over the serial connection.", |
| "longDescription": "This property shall indicate parity information for a serial connection.", |
| "readonly": false |
| }, |
| "PinOut": { |
| "anyOf": [ |
| { |
| "$ref": "#/definitions/PinOut" |
| }, |
| { |
| "type": "null" |
| } |
| ], |
| "description": "The physical pin configuration needed for a serial connector.", |
| "longDescription": "This property shall indicate the physical pin out for the serial connection.", |
| "readonly": true |
| }, |
| "SignalType": { |
| "$ref": "#/definitions/SignalType", |
| "description": "The type of signal used for the communication connection - RS232 or RS485.", |
| "longDescription": "This property shall indicate the type of serial signalling that will be utilized for the serial connection.", |
| "readonly": true |
| }, |
| "StopBits": { |
| "$ref": "#/definitions/StopBits", |
| "description": "The period of time before the next start bit is transmitted.", |
| "longDescription": "This property shall indicate the stop bits for the serial connection.", |
| "readonly": false |
| } |
| }, |
| "required": [ |
| "Id", |
| "Name" |
| ], |
| "type": "object" |
| }, |
| "SignalType": { |
| "enum": [ |
| "Rs232", |
| "Rs485" |
| ], |
| "enumDescriptions": { |
| "Rs232": "The serial interface follows RS232.", |
| "Rs485": "The serial interface follows RS485." |
| }, |
| "type": "string" |
| }, |
| "StopBits": { |
| "enum": [ |
| "1", |
| "2" |
| ], |
| "enumDescriptions": { |
| "1": "1 stop bit following the data bits.", |
| "2": "2 stop bits following the data bits." |
| }, |
| "type": "string" |
| } |
| }, |
| "title": "#SerialInterface.v1_1_2.SerialInterface" |
| } |