 | // Copyright (c) 2018 Intel Corporation | 
 | // | 
 | // Licensed under the Apache License, Version 2.0 (the "License"); | 
 | // you may not use this file except in compliance with the License. | 
 | // You may obtain a copy of the License at | 
 | // | 
 | //      http://www.apache.org/licenses/LICENSE-2.0 | 
 | // | 
 | // Unless required by applicable law or agreed to in writing, software | 
 | // distributed under the License is distributed on an "AS IS" BASIS, | 
 | // WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. | 
 | // See the License for the specific language governing permissions and | 
 | // limitations under the License. | 
 | */ | 
 |  | 
 | #include "PwmSensor.hpp" | 
 |  | 
 | #include "SensorPaths.hpp" | 
 | #include "Utils.hpp" | 
 | #include "sensor.hpp" | 
 |  | 
 | #include <phosphor-logging/lg2.hpp> | 
 | #include <sdbusplus/asio/connection.hpp> | 
 | #include <sdbusplus/asio/object_server.hpp> | 
 |  | 
 | #include <cmath> | 
 | #include <cstdint> | 
 | #include <fstream> | 
 | #include <memory> | 
 | #include <stdexcept> | 
 | #include <string> | 
 |  | 
 | static constexpr double sysPwmMax = 255.0; | 
 | static constexpr double psuPwmMax = 100.0; | 
 | static constexpr double defaultPwm = 30.0; | 
 | static constexpr double targetIfaceMax = sysPwmMax; | 
 |  | 
 | PwmSensor::PwmSensor(const std::string& pwmname, const std::string& sysPath, | 
 |                      std::shared_ptr<sdbusplus::asio::connection>& conn, | 
 |                      sdbusplus::asio::object_server& objectServer, | 
 |                      const std::string& sensorConfiguration, | 
 |                      const std::string& sensorType, bool isValueMutable) : | 
 |     sysPath(sysPath), objectServer(objectServer), | 
 |     name(sensor_paths::escapePathForDbus(pwmname)) | 
 | { | 
 |     // add interface under sensor and Control.FanPwm as Control is used | 
 |     // in obmc project, also add sensor so it can be viewed as a sensor | 
 |     sensorInterface = objectServer.add_interface( | 
 |         "/xyz/openbmc_project/sensors/fan_pwm/" + name, | 
 |         "xyz.openbmc_project.Sensor.Value"); | 
 |     uint32_t pwmValue = getValue(false); | 
 |     if (sensorType == "PSU") | 
 |     { | 
 |         pwmMax = psuPwmMax; | 
 |     } | 
 |     else | 
 |     { | 
 |         pwmMax = sysPwmMax; | 
 |     } | 
 |  | 
 |     if (pwmValue == 0U) | 
 |     { | 
 |         // default pwm to non 0 | 
 |         pwmValue = static_cast<uint32_t>(pwmMax * (defaultPwm / 100.0)); | 
 |         setValue(pwmValue); | 
 |     } | 
 |     double fValue = 100.0 * (static_cast<double>(pwmValue) / pwmMax); | 
 |     sensorInterface->register_property( | 
 |         "Value", fValue, | 
 |         [this](const double& req, double& resp) { | 
 |             if (!std::isfinite(req)) | 
 |             { | 
 |                 // Reject attempted change, if to NaN or other non-numeric | 
 |                 return -1; | 
 |             } | 
 |             if (req > 100.0 || req < 0.0) | 
 |             { | 
 |                 // TODO(): It does not seem desirable to halt daemon here, | 
 |                 // probably should just reject the change, continue running? | 
 |                 throw std::runtime_error("Value out of range"); | 
 |                 return -1; | 
 |             } | 
 |  | 
 |             double reqValue = (req / 100.0) * pwmMax; | 
 |             double respValue = (resp / 100.0) * pwmMax; | 
 |             auto reqInt = static_cast<uint32_t>(std::round(reqValue)); | 
 |             auto respInt = static_cast<uint32_t>(std::round(respValue)); | 
 |             // Avoid floating-point equality, compare as integers | 
 |             if (reqInt == respInt) | 
 |             { | 
 |                 return 1; | 
 |             } | 
 |             setValue(reqInt); | 
 |             resp = req; | 
 |  | 
 |             controlInterface->signal_property("Target"); | 
 |  | 
 |             return 1; | 
 |         }, | 
 |         [this](double& curVal) { | 
 |             double currScaled = (curVal / 100.0) * pwmMax; | 
 |             auto currInt = static_cast<uint32_t>(std::round(currScaled)); | 
 |             auto getInt = getValue(); | 
 |             // Avoid floating-point equality, compare as integers | 
 |             if (currInt != getInt) | 
 |             { | 
 |                 double getScaled = | 
 |                     100.0 * (static_cast<double>(getInt) / pwmMax); | 
 |                 curVal = getScaled; | 
 |                 controlInterface->signal_property("Target"); | 
 |                 sensorInterface->signal_property("Value"); | 
 |             } | 
 |             return curVal; | 
 |         }); | 
 |     // pwm sensor interface is in percent | 
 |     sensorInterface->register_property("MaxValue", static_cast<double>(100)); | 
 |     sensorInterface->register_property("MinValue", static_cast<double>(0)); | 
 |     sensorInterface->register_property("Unit", sensor_paths::unitPercent); | 
 |  | 
 |     controlInterface = objectServer.add_interface( | 
 |         "/xyz/openbmc_project/control/fanpwm/" + name, | 
 |         "xyz.openbmc_project.Control.FanPwm"); | 
 |     controlInterface->register_property( | 
 |         "Target", static_cast<uint64_t>(pwmValue), | 
 |         [this](const uint64_t& req, uint64_t& resp) { | 
 |             if (req > static_cast<uint64_t>(targetIfaceMax)) | 
 |             { | 
 |                 throw std::runtime_error("Value out of range"); | 
 |                 return -1; | 
 |             } | 
 |             if (req == resp) | 
 |             { | 
 |                 return 1; | 
 |             } | 
 |             auto scaledValue = static_cast<double>(req) / targetIfaceMax; | 
 |             auto roundValue = std::round(scaledValue * pwmMax); | 
 |             setValue(static_cast<uint32_t>(roundValue)); | 
 |             resp = req; | 
 |  | 
 |             sensorInterface->signal_property("Value"); | 
 |  | 
 |             return 1; | 
 |         }, | 
 |         [this](uint64_t& curVal) { | 
 |             auto getInt = getValue(); | 
 |             auto scaledValue = static_cast<double>(getInt) / pwmMax; | 
 |             auto roundValue = std::round(scaledValue * targetIfaceMax); | 
 |             auto value = static_cast<uint64_t>(roundValue); | 
 |             if (curVal != value) | 
 |             { | 
 |                 curVal = value; | 
 |                 controlInterface->signal_property("Target"); | 
 |                 sensorInterface->signal_property("Value"); | 
 |             } | 
 |             return curVal; | 
 |         }); | 
 |  | 
 |     sensorInterface->initialize(); | 
 |     controlInterface->initialize(); | 
 |  | 
 |     if (isValueMutable) | 
 |     { | 
 |         valueMutabilityInterface = | 
 |             std::make_shared<sdbusplus::asio::dbus_interface>( | 
 |                 conn, sensorInterface->get_object_path(), | 
 |                 valueMutabilityInterfaceName); | 
 |         valueMutabilityInterface->register_property("Mutable", true); | 
 |         if (!valueMutabilityInterface->initialize()) | 
 |         { | 
 |             lg2::error("error initializing sensor value mutability interface"); | 
 |             valueMutabilityInterface = nullptr; | 
 |         } | 
 |     } | 
 |  | 
 |     association = objectServer.add_interface( | 
 |         "/xyz/openbmc_project/sensors/fan_pwm/" + name, association::interface); | 
 |  | 
 |     // PowerSupply sensors should be associated with chassis board path | 
 |     // and inventory along with psu object. | 
 |     if (sensorType == "PSU") | 
 |     { | 
 |         createInventoryAssoc(conn, association, sensorConfiguration); | 
 |     } | 
 |     else | 
 |     { | 
 |         createAssociation(association, sensorConfiguration); | 
 |     } | 
 | } | 
 | PwmSensor::~PwmSensor() | 
 | { | 
 |     objectServer.remove_interface(sensorInterface); | 
 |     objectServer.remove_interface(controlInterface); | 
 |     objectServer.remove_interface(association); | 
 | } | 
 |  | 
 | void PwmSensor::setValue(uint32_t value) | 
 | { | 
 |     std::ofstream ref(sysPath); | 
 |     if (!ref.good()) | 
 |     { | 
 |         throw std::runtime_error("Bad Write File"); | 
 |     } | 
 |     ref << value; | 
 | } | 
 |  | 
 | // on success returns pwm, on failure throws except on initialization, where it | 
 | // prints an error and returns 0 | 
 | uint32_t PwmSensor::getValue(bool errThrow) | 
 | { | 
 |     std::ifstream ref(sysPath); | 
 |     if (!ref.good()) | 
 |     { | 
 |         lg2::error("Error opening '{PATH}'", "PATH", sysPath); | 
 |         return 0; | 
 |     } | 
 |     std::string line; | 
 |     if (!std::getline(ref, line)) | 
 |     { | 
 |         lg2::error("Error reading pwm at '{PATH}'", "PATH", sysPath); | 
 |         return 0; | 
 |     } | 
 |     try | 
 |     { | 
 |         uint32_t value = std::stoi(line); | 
 |         return value; | 
 |     } | 
 |     catch (const std::invalid_argument&) | 
 |     { | 
 |         lg2::error("Error converting pwm"); | 
 |         // throw if not initial read to be caught by dbus bindings | 
 |         if (errThrow) | 
 |         { | 
 |             throw std::runtime_error("Bad Read"); | 
 |         } | 
 |     } | 
 |     return 0; | 
 | } |