blob: f40c417953ee24365de52222a2063665758b3d8d [file] [log] [blame]
HOMEPAGE = "github.com/openbmc/phosphor-pid-control"
LICENSE = "Apache-2.0"
LIC_FILES_CHKSUM = "file://LICENSE;md5=86d3f3a95c324c9479bd8986968f4327"
SUMMARY = "Phosphor PID Fan Control"
DESCRIPTION = "Fan Control"
PR = "r1"
SRC_URI = "git://github.com/openbmc/phosphor-pid-control"
SRCREV = "ce15e02f6859df404cc9c1e39b40496f3e7a15f6"
S = "${WORKDIR}/git"
inherit autotools pkgconfig
inherit pythonnative
inherit phosphor-pid-control
inherit obmc-phosphor-ipmiprovider-symlink
# Each platform will need a service file that starts
# at an appropriate time per system. For instance, if
# your system relies on passive dbus for fans or other
# sensors then it may be prudent to wait for all of them.
DEPENDS += "autoconf-archive-native"
DEPENDS += "python-pyyaml-native"
DEPENDS += "python-mako-native"
DEPENDS += "sdbusplus"
DEPENDS += "phosphor-logging"
DEPENDS += "libevdev"
DEPENDS += "libconfig"
# We depend on someone providing their system's configuration.
DEPENDS += "virtual/phosphor-fans-sensor-inventory"
# We depend on this to be built first so we can build our providers.
DEPENDS += "phosphor-ipmi-host"
RDEPENDS_${PN} += "sdbusplus phosphor-dbus-interfaces"
FILES_${PN} = "${sbindir}/swampd ${sbindir}/setsensor"
# The following installs the OEM IPMI handler for the fan controls.
FILES_${PN}_append = " ${libdir}/ipmid-providers/lib*${SOLIBS}"
FILES_${PN}_append = " ${libdir}/host-ipmid/lib*${SOLIBS}"
FILES_${PN}_append = " ${libdir}/net-ipmid/lib*${SOLIBS}"
FILES_${PN}-dev_append = " ${libdir}/ipmid-providers/lib*${SOLIBSDEV} ${libdir}/ipmid-providers/*.la"
EXTRA_OECONF = "SENSOR_YAML_GEN=${STAGING_DIR_NATIVE}${sensor_datadir}/sensor-list.yaml \
PID_YAML_GEN=${STAGING_DIR_NATIVE}${sensor_datadir}/pid-list.yaml \
ZONE_YAML_GEN=${STAGING_DIR_NATIVE}${sensor_datadir}/zone-info.yaml"
HOSTIPMI_PROVIDER_LIBRARY += "libmanualcmds.so"