| OBMC_BMC_INSTANCES ?= "0" |
| OBMC_CHASSIS_INSTANCES ?= "0" |
| OBMC_CHECKSTOP_INSTANCES ?= "0" |
| OBMC_FAN_INSTANCES ?= "" |
| OBMC_HOST_INSTANCES ?= "0" |
| OBMC_POWER_BUTTON_INSTANCES ?= "0" |
| OBMC_POWER_INSTANCES ?= "0" |
| OBMC_RESET_BUTTON_INSTANCES ?= "0" |
| OBMC_WATCHDOG_INSTANCES ?= "0" |
| |
| PREFERRED_PROVIDER_virtual/obmc-chassis-mgmt ?= "obmc-phosphor-chassisd" |
| PREFERRED_PROVIDER_virtual/obmc-event-mgmt ?= "obmc-phosphor-event" |
| PREFERRED_PROVIDER_virtual/obmc-fan-mgmt ?= "obmc-phosphor-fand" |
| PREFERRED_PROVIDER_virtual/obmc-flash-mgmt ?= "obmc-phosphor-flashd" |
| PREFERRED_PROVIDER_virtual/obmc-host-ipmi-hw ?= "phosphor-ipmi-hw-example" |
| |
| # obmc-bmc-state-manager |
| # |
| # Provides an implementation of the xyz.openbmc_project.State.BMC |
| # interface. |
| VIRTUAL-RUNTIME_obmc-bmc-state-manager ?= "phosphor-state-manager-bmc" |
| |
| # obmc-chassis-state-manager |
| # |
| # Provides an implementation of the xyz.openbmc_project.State.Chassis |
| # interface. |
| VIRTUAL-RUNTIME_obmc-chassis-state-manager ?= "phosphor-state-manager-chassis" |
| |
| # obmc-host-state-manager |
| # |
| # Provides an implementation of the xyz.openbmc_project.State.Host |
| # interface. |
| VIRTUAL-RUNTIME_obmc-host-state-manager ?= "phosphor-state-manager-host" |
| |
| # obmc-discover-system-state |
| # |
| # Provides an implementation of phosphor-discover-system-state, which, if the |
| # host is powered off, will check the current power policy and, if necessary, |
| # power the host back on. |
| VIRTUAL-RUNTIME_obmc-discover-system-state ?= "phosphor-state-manager-discover" |
| |
| # obmc-host-check |
| # |
| # Provides an implementation of phosphor-host-check, which will determine |
| # if the host is running after a BMC reboot and create the necessary file |
| # to indicate to host services that the host is running |
| VIRTUAL-RUNTIME_obmc-host-check ?= "phosphor-state-manager-host-check" |
| |
| # obmc-fan-presence |
| # |
| # Provides implementations of fan presence detection |
| VIRTUAL-RUNTIME_obmc-fan-presence ?= "phosphor-fan-presence-tach" |
| |
| # obmc-fan-control |
| # |
| # Provides implementations of fan control |
| VIRTUAL-RUNTIME_obmc-fan-control ?= "phosphor-fan-control" |
| |
| # obmc-inventory-manager |
| # |
| # Provides an implementation of the xyz.openbmc_project.Inventory.Manager |
| # interface. |
| VIRTUAL-RUNTIME_obmc-inventory-manager ?= "phosphor-inventory-manager" |
| |
| # obmc-led-manager |
| # |
| # Provides an implementation of the xyz.openbmc_project.ledmanager interface. |
| VIRTUAL-RUNTIME_obmc-leds-manager ?= "phosphor-led-manager" |
| |
| # obmc-led-sysfs |
| # |
| # Provides an implementation of xyz.openbmc_project.Led.Physical for |
| # Linux kernel LED subsystem LEDs. |
| VIRTUAL-RUNTIME_obmc-leds-sysfs ?= "phosphor-led-sysfs" |
| |
| # obmc-bmc-code-mgr |
| # |
| # Provides an implementation of the xyz.openbmc_project.Software.BMC.Version |
| # interface. |
| VIRTUAL-RUNTIME_obmc-bmc-code-mgr ?= "phosphor-software-manager-version" |
| |
| # obmc-bmc-download-mgr |
| # |
| # Provides an implementation of the xyz.openbmc_project.Common.TFTP |
| # interface. |
| VIRTUAL-RUNTIME_obmc-bmc-download-mgr ?= "phosphor-software-manager-download-mgr" |
| |
| PREFERRED_PROVIDER_virtual/obmc-logging-mgmt ?= "phosphor-logging" |
| PREFERRED_PROVIDER_virtual/obmc-net-ipmi ?= "phosphor-ipmi-net" |
| |
| # obmc-sensors-hwmon |
| # |
| # Provides an implementation of xyz.openbmc_project.Sensor.Value |
| # for hwmon sensors. |
| VIRTUAL-RUNTIME_obmc-sensors-hwmon ?= "phosphor-hwmon" |
| |
| PREFERRED_PROVIDER_virtual/obmc-settings-mgmt ?= "phosphor-settings" |
| PREFERRED_PROVIDER_virtual/obmc-system-mgmt ?= "obmc-phosphor-sysd" |
| PREFERRED_PROVIDER_virtual/obmc-user-mgmt ?= "obmc-phosphor-user" |
| PREFERRED_PROVIDER_virtual/obmc-wsgihost ?= "phosphor-gevent" |
| |
| # phosphor-hwmon-config |
| # |
| # The phosphor-hwmon package can have its configuration generated |
| # automatically if the MRW feature is enabled. |
| VIRTUAL-RUNTIME_phosphor-hwmon-config ?= \ |
| "${@cf_enabled(d, 'obmc-mrw', 'phosphor-hwmon-config-mrw')}" |
| |
| # virtual/phosphor-ipmi-fru-hostfw-config |
| # |
| # The phosphor-ipmi-fru application is data-driven and requires an input |
| # mapping of how the host firmware reports inventory via IPMI. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-ipmi-fru build process. |
| PREFERRED_PROVIDER_virtual/phosphor-ipmi-fru-hostfw-config ?= "phosphor-ipmi-fru-hostfw-config-example-native" |
| |
| # The phosphor-ipmi-fru application is data-driven and requires an input |
| # mapping of IPMI inventory metadata to DBus objects interfaces and properties. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-ipmi-fru build process in the native sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-ipmi-fru-inventory ?= \ |
| "${@cf_enabled(d, 'obmc-mrw', 'phosphor-ipmi-fru-inventory-mrw-native', 'phosphor-ipmi-fru-inventory-example-native')}" |
| PREFERRED_PROVIDER_virtual/phosphor-ipmi-fru-properties ?= \ |
| "${@cf_enabled(d, 'obmc-mrw', 'phosphor-ipmi-fru-properties-mrw-native', 'phosphor-ipmi-fru-properties-native')}" |
| |
| # The phosphor-led-manager application is data-driven and requires an input |
| # yaml of LED group and members. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-led-manager build process in the native sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-led-manager-config-native ?= \ |
| "${@cf_enabled(d, 'obmc-mrw', 'phosphor-led-manager-config-mrw-native', 'phosphor-led-manager-config-example-native')}" |
| |
| # The phosphor-host-ipmid application is data-driven and requires an input |
| # mapping of IPMI inventory sensor metadata to DBus objects interfaces and properties. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-host-ipmid build process in the native sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-ipmi-sensor-inventory ?= \ |
| "${@cf_enabled(d, 'obmc-mrw', 'phosphor-ipmi-sensor-inventory-mrw-native', 'phosphor-ipmi-sensor-inventory-native')}" |
| |
| # The phosphor-logging application has a data driven plugin that adds FRU |
| # callout information to error logs, when applications generating error logs |
| # add the requisite callout metadata to the systemd journal. The plugin requires |
| # an input mapping of Linux sysfs devices to OpenBMC DBus objects. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-logging build process in the native sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-logging-callouts ?= \ |
| "${@cf_enabled(d, 'obmc-mrw', 'phosphor-logging-callouts-mrw-native', 'phosphor-logging-callouts-example-native')}" |
| |
| # The phosphor-fan-presence application is data driven and requires an |
| # input YAML that maps fans to their tach sensors. |
| # This virtual is a native recipe that provides that mapping by installing |
| # configuration files in the format and native sysroot location expected by |
| # the phosphor-fan-presence build process in the native sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-fan-presence-config ?= \ |
| "${@cf_enabled(d, 'obmc-mrw', 'phosphor-fan-presence-mrw-native', 'phosphor-fan-presence-example-native')}" |
| |
| # The phosphor-fan-control application is data driven and requires a YAML |
| # file to define the fans in the system. |
| # This virtual is a native recipe that provides that definition by installing |
| # the YAML file in the format and native sysroot location expected by |
| # the phosphor-fan-control build process in the native sysroot. |
| PREFERRED_PROVIDER_virtual/phosphor-fan-control-fan-config ?= \ |
| "${@cf_enabled(d, 'obmc-mrw', 'phosphor-fan-control-fan-config-mrw-native', 'phosphor-fan-control-fan-config-native')}" |
| |
| OBMC_DBUS_PATH_ROOT ?= "/xyz/openbmc_project" |
| OBMC_DBUS_IFACE_ROOT ?= "xyz.openbmc_project" |