blob: 1a178a998ef60c3b1f58f84073f1ca57f1c215ce [file] [log] [blame]
SUMMARY = "OpenBMC - Applications"
PR = "r1"
inherit packagegroup
PROVIDES = "${PACKAGES}"
PACKAGES = " \
${PN}-bmc-state-mgmt \
${PN}-chassis-state-mgmt \
${PN}-extras \
${PN}-extrasdev \
${PN}-extrasdevtools \
${PN}-fan-control \
${PN}-host-state-mgmt \
${PN}-inventory \
${PN}-leds \
${PN}-logging \
${PN}-sensors \
${PN}-software \
${PN}-host-check-mgmt \
${PN}-debug-collector \
${PN}-settings \
${PN}-network \
${PN}-user-mgmt \
"
SUMMARY_${PN}-bmc-state-mgmt = "BMC state management"
RDEPENDS_${PN}-bmc-state-mgmt = " \
${VIRTUAL-RUNTIME_obmc-bmc-state-manager} \
"
SUMMARY_${PN}-chassis-state-mgmt = "Chassis state management"
RDEPENDS_${PN}-chassis-state-mgmt = " \
${VIRTUAL-RUNTIME_obmc-chassis-state-manager} \
"
SUMMARY_${PN}-extras = "Extra features"
RDEPENDS_${PN}-extras = " \
phosphor-rest \
phosphor-dbus-monitor \
phosphor-systemd-policy \
dbus-broker \
"
SUMMARY_${PN}-extrasdev = "Development features"
RDEPENDS_${PN}-extrasdev = " \
rest-dbus \
"
SUMMARY_${PN}-extrasdevtools = "Development tools"
RDEPENDS_${PN}-extrasdevtools = " \
"
# Use the fan control package group for applications
# implementing fan control or system fan policy only.
# Applications that create inventory or sensors should
# be added those respective package groups instead.
SUMMARY_${PN}-fan-control = "Fan control"
RDEPENDS_${PN}-fan-control = " \
${VIRTUAL-RUNTIME_obmc-fan-control} \
phosphor-fan-monitor \
"
SUMMARY_${PN}-host-state-mgmt = "Host state management"
RDEPENDS_${PN}-host-state-mgmt = " \
${VIRTUAL-RUNTIME_obmc-host-state-manager} \
${VIRTUAL-RUNTIME_obmc-discover-system-state} \
"
SUMMARY_${PN}-inventory = "Inventory applications"
RDEPENDS_${PN}-inventory = " \
${VIRTUAL-RUNTIME_obmc-inventory-manager} \
${VIRTUAL-RUNTIME_obmc-fan-presence} \
"
SUMMARY_${PN}-leds = "LED applications"
RDEPENDS_${PN}-leds = " \
${VIRTUAL-RUNTIME_obmc-leds-manager} \
${VIRTUAL-RUNTIME_obmc-leds-sysfs} \
${VIRTUAL-RUNTIME_obmc-led-monitor} \
"
SUMMARY_${PN}-logging = "Logging applications"
RDEPENDS_${PN}-logging = " \
phosphor-logging \
rsyslog \
phosphor-rsyslog-config \
"
SUMMARY_${PN}-sensors = "Sensor applications"
RDEPENDS_${PN}-sensors = " \
${VIRTUAL-RUNTIME_obmc-sensors-hwmon} \
"
# These packages are not required with UBI enabled
${PN}-software-extras = " \
obmc-flash-bmc \
obmc-mgr-download \
"
${PN}-software-extras_df-obmc-ubi-fs = " \
phosphor-image-signing \
phosphor-software-manager-updater-ubi \
"
SUMMARY_${PN}-software = "Software applications"
RDEPENDS_${PN}-software = " \
${VIRTUAL-RUNTIME_obmc-bmc-download-mgr} \
${VIRTUAL-RUNTIME_obmc-bmc-updater} \
${VIRTUAL-RUNTIME_obmc-bmc-version} \
${${PN}-software-extras} \
"
SUMMARY_${PN}-debug-collector = "BMC debug collector"
RDEPENDS_${PN}-debug-collector = " \
${VIRTUAL-RUNTIME_obmc-dump-manager} \
${VIRTUAL-RUNTIME_obmc-dump-monitor} \
phosphor-debug-collector-dreport \
phosphor-debug-collector-scripts \
"
SUMMARY_${PN}-settings = "Settings applications"
RDEPENDS_${PN}-settings = " \
${VIRTUAL-RUNTIME_obmc-settings-mgmt} \
"
SUMMARY_${PN}-network = "BMC Network Manager"
RDEPENDS_${PN}-network = " \
${VIRTUAL-RUNTIME_obmc-network-manager} \
"
SUMMARY_${PN}-user-mgmt = "User management applications"
RDEPENDS_${PN}-user-mgmt = " \
${VIRTUAL-RUNTIME_obmc-user-mgmt} \
${@bb.utils.contains('DISTRO_FEATURES', 'ldap', 'nss-pam-ldapd', '', d)} \
"