| FILESEXTRAPATHS_prepend_gsj := "${THISDIR}/${PN}:" |
| SRC_URI_append_gsj = " file://config-8ssd.json" |
| SRC_URI_append_gsj = " file://config-2ssd.json" |
| SRC_URI_append_gsj = " file://fan-control.sh" |
| SRC_URI_append_gsj = " file://fan-full-speed.sh" |
| SRC_URI_append_gsj = " file://phosphor-pid-control.service" |
| SRC_URI_append_gsj = " file://fan-reboot-control.service" |
| |
| FILES_${PN}_append_gsj = " ${datadir}/swampd/config-8ssd.json" |
| FILES_${PN}_append_gsj = " ${datadir}/swampd/config-2ssd.json" |
| FILES_${PN}_append_gsj = " ${bindir}/fan-control.sh" |
| FILES_${PN}_append_gsj = " ${bindir}/fan-full-speed.sh" |
| |
| inherit systemd |
| RDEPENDS_${PN} += "bash" |
| |
| SYSTEMD_SERVICE_${PN}_append_gsj = " phosphor-pid-control.service" |
| SYSTEMD_SERVICE_${PN}_append_gsj = " fan-reboot-control.service" |
| |
| do_install_append_gsj() { |
| install -d ${D}/${bindir} |
| install -m 0755 ${WORKDIR}/fan-control.sh ${D}/${bindir} |
| install -m 0755 ${WORKDIR}/fan-full-speed.sh ${D}/${bindir} |
| |
| install -d ${D}${datadir}/swampd |
| install -m 0644 -D ${WORKDIR}/config-8ssd.json \ |
| ${D}${datadir}/swampd/config-8ssd.json |
| install -m 0644 -D ${WORKDIR}/config-2ssd.json \ |
| ${D}${datadir}/swampd/config-2ssd.json |
| |
| install -d ${D}${systemd_unitdir}/system/ |
| install -m 0644 ${WORKDIR}/phosphor-pid-control.service \ |
| ${D}${systemd_unitdir}/system |
| install -m 0644 ${WORKDIR}/fan-reboot-control.service \ |
| ${D}${systemd_unitdir}/system |
| } |