| *** Settings *** |
| |
| Documentation Operational checks for fans. |
| |
| # Test Parameters: |
| # OPENBMC_HOST The BMC host name or IP address. |
| # OPENBMC_USERNAME The userID to login to the BMC as. |
| # OPENBMC_PASSWORD The password for OPENBMC_USERNAME. |
| # OS_HOST The OS host name or IP Address. |
| # OS_USERNAME The OS login userid (usually root). |
| # OS_PASSWORD The password for the OS login. |
| # |
| # Approximate run time: 8 minutes. |
| |
| Resource ../syslib/utils_os.robot |
| Resource ../lib/logging_utils.robot |
| Resource ../lib/utils.robot |
| Resource ../lib/fan_utils.robot |
| |
| Suite Setup Suite Setup Execution |
| Test Teardown Test Teardown Execution |
| |
| |
| *** Variables *** |
| |
| # The fan speed-monitoring daemon takes less than one second to |
| # notice a fan failure. Allow system_response_time before checking |
| # if there was a measurable response to the daemon, such as an increase |
| # in RPMs of the other fans. |
| ${system_response_time} 30s |
| |
| # The @{fan_names} list holds the names of the fans in the system. |
| @{fan_names} |
| |
| # Fan state values. |
| ${fan_functional} ${1} |
| ${fan_nonfunctional} ${0} |
| |
| |
| *** Test Cases *** |
| |
| |
| Check Number Of Fans With Power On |
| [Documentation] Verify system has the minimum number of fans. |
| [Tags] Check_Number_Of_Fans_With_Power_On |
| |
| @{fan_names} Create List |
| # Populate the list with the names of the fans in the system. |
| ${fan_names}= Get Fan Names ${fan_names} |
| Set Suite Variable ${fan_names} children=true |
| |
| ${number_of_fans}= Get Length ${fan_names} |
| |
| # Determine if system is water cooled. |
| ${water_coooled}= Is Water Cooled |
| |
| Verify Minimum Number Of Fans With Cooling Type ${number_of_fans} |
| ... ${water_coooled} |
| |
| |
| Check Number Of Fan Monitors With Power On |
| [Documentation] Verify monitors are present when power on. |
| [Tags] Check_Number_Of_Fan_Monitors_With_Power_On |
| |
| Verify Fan Monitors With State On |
| |
| |
| Verify Fan RPM Increase |
| [Documentation] Verify that RPMs of working fans increase when one fan |
| ... is disabled. |
| [Tags] Verify_Fan_RPM_Increase |
| # A non-functional fan should cause an error log and |
| # an enclosure LED will light. The other fans should speed up. |
| |
| # Any fan at this speed or greater will be considered to be at maximum RPM. |
| ${max_fan_rpm}= Set Variable 10400 |
| |
| # Choose a fan to test with, e.g., fan1. |
| ${test_fan_name}= Get From List ${fan_names} 1 |
| Rpvars test_fan_name |
| |
| ${initial_speed}= Get Target Speed Of Fans |
| Rpvars initial_speed |
| |
| # If initial speed is not already at maximum, set expect_increase. |
| # This flag is used later to determine if speed checking is |
| # to be done or not. |
| ${expect_increase}= Run Keyword If |
| ... ${initial_speed} < ${max_fan_rpm} |
| ... Set Variable 1 ELSE Set Variable 0 |
| |
| Set Fan State ${test_fan_name} ${fan_nonfunctional} |
| Sleep ${system_response_time} |
| |
| Verify System Error Indication Due To Fans |
| |
| # Verify the error log is for test_fan_name. |
| ${elog_entries}= Get Logging Entry List |
| :FOR ${elog_entry} IN @{elog_entries} |
| \ ${elog_entry_callout}= Set Variable ${elog_entry}/callout |
| \ ${endpoint}= Read Attribute ${elog_entry_callout} endpoints |
| \ ${endpoint_name}= Get From List ${endpoint} 0 |
| \ Should Contain ${endpoint_name} ${test_fan_name} |
| ... msg=Error log present but not for ${test_fan_name}. |
| |
| ${new_fan_speed}= Get Target Speed Of Fans |
| Rpvars expect_increase initial_speed new_fan_speed |
| |
| # Fail if current fan speed did not increase past the initial |
| # speed, but do this check only if not at maximum speed to begin with. |
| Run Keyword If |
| ... ${expect_increase} == 1 and ${new_fan_speed} < ${initial_speed} |
| ... Fail msg=Remaining fans did not increase speed with loss of one fan. |
| |
| # Recover the fan. |
| Set Fan State ${test_fan_name} ${fan_functional} |
| Sleep ${system_response_time} |
| |
| Delete Error Logs |
| Sleep 2s |
| |
| # Enclosure LEDs should go off immediately after deleting the error logs. |
| Verify Front And Rear LED State Off |
| |
| ${restored_fan_speed}= Get Target Speed Of Fans |
| Rpvars new_fan_speed restored_fan_speed |
| |
| # Fan speed should lower because the fan is now functional again. |
| Run Keyword If |
| ... ${expect_increase} == 1 and ${new_fan_speed} < ${restored_fan_speed} |
| ... Fail msg=Fans did not recover speed with all fans functional again. |
| |
| |
| Verify System Shutdown Due To Fans |
| [Documentation] Shut down when not enough fans. |
| [Tags] Verify_System_Shutdown_Due_To_Fans |
| |
| # Set fans to be non-functional. |
| :FOR ${fan_name} IN @{fan_names} |
| \ Set Fan State ${fan_name} ${fan_nonfunctional} |
| |
| # System should notice the non-functional fans and power-off the |
| # system. The Wait For PowerOff keyword will time-out and report |
| # an error if power off does not happen within a reasonable time. |
| Wait For PowerOff |
| |
| Verify System Error Indication Due To Fans |
| |
| # Verify there is an error log because of the shutdown. |
| ${expect}= Catenate |
| ... xyz.openbmc_project.State.Shutdown.Inventory.Error.Fan |
| ${elog_entries}= Get Logging Entry List |
| :FOR ${elog_entry} IN @{elog_entries} |
| \ ${elog_message}= Read Attribute ${elog_entry} Message |
| \ ${found}= Set Variable 1 |
| \ Run Keyword If '${elog_message}' == '${expect}' Exit For Loop |
| \ ${found}= Set Variable 0 |
| Run Keyword If not ${found} Fail |
| ... msg=No error log for event Shutdown.Inventory.Error.Fan. |
| |
| |
| *** Keywords *** |
| |
| |
| Reset Fans |
| [Documentation] Set the fans to functional state. |
| # Set state of fans to functional by writing 1 to the Functional |
| # attribute of each fan in the @{fan_names} list. If @{fan_names} |
| # is empty nothing is done. |
| |
| # Description of Argument(s): |
| # fans Suite Variable which is a list containing the |
| # names of the fans (e.g., fan0 fan2 fan3). |
| |
| :FOR ${fan_name} IN @{fan_names} |
| \ Set Fan State ${fan_name} ${fan_functional} |
| |
| |
| Suite Setup Execution |
| [Documentation] Do the pre-test setup. |
| |
| REST Power On stack_mode=skip |
| Delete All Error Logs |
| Set System LED State front_fault Off |
| Set System LED State rear_fault Off |
| |
| |
| Test Teardown Execution |
| [Documentation] Do the post-test teardown. |
| |
| FFDC On Test Case Fail |
| Reset Fans |
| Delete Error Logs |
| Set System LED State front_fault Off |
| Set System LED State rear_fault Off |