| import os |
| from robot.libraries.BuiltIn import BuiltIn |
| |
| OPENBMC_BASE_URI = '/xyz/openbmc_project/' |
| OPENBMC_BASE_DBUS = 'xyz.openbmc_project.' |
| |
| # org open power base URI. |
| OPENPOWER_BASE_URI = '/org/open_power/' |
| OPENPOWER_CONTROL = OPENPOWER_BASE_URI + 'control/' |
| OPENPOWER_SENSORS = OPENPOWER_BASE_URI + 'sensors/' |
| |
| # REST URI base endpoint paths. |
| CONTROL_URI = OPENBMC_BASE_URI + 'control/' |
| # Continue to keep to support legacy code. |
| SETTINGS_URI = '/org/openbmc/settings/' |
| WATCHDOG_URI = OPENBMC_BASE_URI + 'watchdog/' |
| TIME_MANAGER_URI = OPENBMC_BASE_URI + 'time/' |
| NETWORK_MANAGER = OPENBMC_BASE_URI + 'network/' |
| NETWORK_RESOURCE = 'xyz.openbmc_project.Network.IP.Protocol.IPv4' |
| # SNMP |
| SNMP_MANAGER_URI = NETWORK_MANAGER + 'snmp/manager/' |
| # Sensors base variables. |
| SENSORS_URI = OPENBMC_BASE_URI + 'sensors/' |
| # Thermal Control base variables |
| THERMAL_CONTROL_URI = CONTROL_URI + 'thermal/0' |
| |
| # State Manager base variables |
| BMC_REBOOT_TRANS = 'xyz.openbmc_project.State.BMC.Transition.Reboot' |
| |
| HOST_POWEROFF_TRANS = 'xyz.openbmc_project.State.Host.Transition.Off' |
| HOST_POWERON_TRANS = 'xyz.openbmc_project.State.Host.Transition.On' |
| HOST_REBOOT_TRANS = 'xyz.openbmc_project.State.Host.Transition.Reboot' |
| HOST_POWEROFF_STATE = 'xyz.openbmc_project.State.Host.HostState.Off' |
| HOST_POWERON_STATE = 'xyz.openbmc_project.State.Host.HostState.Running' |
| |
| CHASSIS_POWEROFF_TRANS = 'xyz.openbmc_project.State.Chassis.Transition.Off' |
| CHASSIS_POWERON_TRANS = 'xyz.openbmc_project.State.Chassis.Transition.On' |
| CHASSIS_POWEROFF_STATE = 'xyz.openbmc_project.State.Chassis.PowerState.Off' |
| CHASSIS_POWERON_STATE = 'xyz.openbmc_project.State.Chassis.PowerState.On' |
| |
| # State Manager URI variables. |
| SYSTEM_STATE_URI = OPENBMC_BASE_URI + 'state/' |
| BMC_STATE_URI = OPENBMC_BASE_URI + 'state/bmc0/' |
| HOST_STATE_URI = OPENBMC_BASE_URI + 'state/host0/' |
| CHASSIS_STATE_URI = OPENBMC_BASE_URI + 'state/chassis0/' |
| HOST_WATCHDOG_URI = OPENBMC_BASE_URI + 'watchdog/host0/' |
| |
| # Logging URI variables |
| BMC_LOGGING_URI = OPENBMC_BASE_URI + 'logging/' |
| BMC_LOGGING_ENTRY = BMC_LOGGING_URI + 'entry/' |
| |
| # Software manager version |
| SOFTWARE_VERSION_URI = OPENBMC_BASE_URI + 'software/' |
| ACTIVE = 'xyz.openbmc_project.Software.Activation.Activations.Active' |
| READY = 'xyz.openbmc_project.Software.Activation.Activations.Ready' |
| INVALID = 'xyz.openbmc_project.Software.Activation.Activations.Invalid' |
| ACTIVATING = 'xyz.openbmc_project.Software.Activation.Activations.Activating' |
| NOTREADY = 'xyz.openbmc_project.Software.Activation.Activations.NotReady' |
| FAILED = 'xyz.openbmc_project.Software.Activation.Activations.Failed' |
| |
| SOFTWARE_ACTIVATION = 'xyz.openbmc_project.Software.Activation' |
| REQUESTED_ACTIVATION = SOFTWARE_ACTIVATION + '.RequestedActivations' |
| REQUESTED_ACTIVE = REQUESTED_ACTIVATION + '.Active' |
| REQUESTED_NONE = REQUESTED_ACTIVATION + '.None' |
| |
| SOFTWARE_PURPOSE = 'xyz.openbmc_project.Software.Version.VersionPurpose' |
| VERSION_PURPOSE_HOST = SOFTWARE_PURPOSE + '.Host' |
| VERSION_PURPOSE_BMC = SOFTWARE_PURPOSE + '.BMC' |
| VERSION_PURPOSE_SYSTEM = SOFTWARE_PURPOSE + '.System' |
| |
| # Image Upload Directory Path |
| IMAGE_UPLOAD_DIR_PATH = '/tmp/images/' |
| |
| # Inventory URI variables |
| HOST_INVENTORY_URI = OPENBMC_BASE_URI + 'inventory/' |
| CHASSIS_INVENTORY_URI = HOST_INVENTORY_URI + 'system/chassis/' |
| MOTHERBOARD_INVENTORY_URI = CHASSIS_INVENTORY_URI + 'motherboard/' |
| |
| # Led URI variable |
| LED_GROUPS_URI = OPENBMC_BASE_URI + 'led/groups/' |
| LED_PHYSICAL_URI = OPENBMC_BASE_URI + 'led/physical/' |
| LED_LAMP_TEST_ASSERTED_URI = LED_GROUPS_URI + 'lamp_test/' |
| LED_PHYSICAL_PS0_URI = LED_PHYSICAL_URI + 'cffps1_69/' |
| LED_PHYSICAL_PS1_URI = LED_PHYSICAL_URI + 'cffps1_68/' |
| LED_PHYSICAL_FAN0_URI = LED_PHYSICAL_URI + 'fan0/' |
| LED_PHYSICAL_FAN2_URI = LED_PHYSICAL_URI + 'fan2/' |
| LED_PHYSICAL_FAN3_URI = LED_PHYSICAL_URI + 'fan3/' |
| |
| # Host control URI variables. |
| CONTROL_HOST_URI = OPENBMC_BASE_URI + 'control/host0/' |
| |
| # Power restore variables. |
| POWER_RESTORE_URI = CONTROL_HOST_URI + 'power_restore_policy' |
| CONTROL_DBUS_BASE = 'xyz.openbmc_project.Control.' |
| |
| RESTORE_LAST_STATE = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.Restore' |
| ALWAYS_POWER_ON = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.AlwaysOn' |
| ALWAYS_POWER_OFF = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.AlwaysOff' |
| |
| # Dump URI variables. |
| DUMP_URI = OPENBMC_BASE_URI + 'dump/bmc/' |
| DUMP_ENTRY_URI = DUMP_URI + 'entry/' |
| DUMP_DOWNLOAD_URI = "/download/dump/" |
| # The path on the BMC where dumps are stored. |
| DUMP_DIR_PATH = "/var/lib/phosphor-debug-collector/dumps/" |
| DUMP_HB_DIR_PATH = "/var/lib/phosphor-debug-collector/hostbootdump/" |
| |
| # Boot progress variables. |
| STATE_DBUS_BASE = 'xyz.openbmc_project.State.' |
| OS_BOOT_START = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.OSStart' |
| OS_BOOT_OFF = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.Unspecified' |
| OS_BOOT_PCI = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.PCIInit' |
| OS_BOOT_SECPCI = STATE_DBUS_BASE + \ |
| 'Boot.Progress.ProgressStages.SecondaryProcInit' |
| OS_BOOT_MEM = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.MemoryInit' |
| OS_BOOT_MOTHERBOARD = STATE_DBUS_BASE + \ |
| 'Boot.Progress.ProgressStages.MotherboardInit' |
| |
| # OperatingSystem status variables. |
| OS_BOOT_COMPLETE = STATE_DBUS_BASE + \ |
| 'OperatingSystem.Status.OSStatus.BootComplete' |
| OS_BOOT_CDROM = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.CDROMBoot' |
| OS_BOOT_ROM = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.ROMBoot' |
| OS_BOOT_PXE = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.PXEBoot' |
| OS_BOOT_CBoot = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.CBoot' |
| OS_BOOT_DiagBoot = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.DiagBoot' |
| |
| # Boot variables. |
| BOOT_SOURCE_DEFAULT = 'xyz.openbmc_project.Control.Boot.Source.Sources.Default' |
| BOOT_SOURCE_NETWORK = 'xyz.openbmc_project.Control.Boot.Source.Sources.Network' |
| BOOT_SOURCE_DISK = 'xyz.openbmc_project.Control.Boot.Source.Sources.Disk' |
| BOOT_SOURCE_CDROM = 'xyz.openbmc_project.Control.Boot.Source.Sources.ExternalMedia' |
| BOOT_MODE_SAFE = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Safe' |
| BOOT_MODE_SETUP = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Setup' |
| BOOT_MODE_REGULAR = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Regular' |
| BOOT_TYPE_LEGACY = 'xyz.openbmc_project.Control.Boot.Type.Types.Legacy' |
| BOOT_TYPE_EFI = 'xyz.openbmc_project.Control.Boot.Type.Types.EFI' |
| |
| # Time variables. |
| TIME_DBUS_BASE = 'xyz.openbmc_project.Time.' |
| BMC_OWNER = TIME_DBUS_BASE + 'Owner.Owners.BMC' |
| HOST_OWNER = TIME_DBUS_BASE + 'Owner.Owners.Host' |
| SPLIT_OWNER = TIME_DBUS_BASE + 'Owner.Owners.Split' |
| BOTH_OWNER = TIME_DBUS_BASE + 'Owner.Owners.Both' |
| NTP_MODE = TIME_DBUS_BASE + 'Synchronization.Method.NTP' |
| MANUAL_MODE = TIME_DBUS_BASE + 'Synchronization.Method.Manual' |
| |
| # User manager variable. |
| BMC_USER_URI = OPENBMC_BASE_URI + 'user/' |
| |
| # LDAP User manager variable. |
| BMC_LDAP_URI = BMC_USER_URI + 'ldap' |
| |
| # The path on the BMC where signed keys are stored. |
| ACTIVATION_DIR_PATH = "/etc/activationdata/" |
| |
| # Redfish variables. |
| REDFISH_BASE_URI = '/redfish/v1/' |
| REDFISH_SESSION = REDFISH_BASE_URI + 'SessionService/Sessions' |
| REDFISH_SESSION_URI = 'SessionService/Sessions/' |
| REDFISH_NW_ETH0 = 'Managers/bmc/EthernetInterfaces/eth0/' |
| REDFISH_NW_ETH0_URI = REDFISH_BASE_URI + REDFISH_NW_ETH0 |
| REDFISH_NW_ETH_IFACE = REDFISH_BASE_URI + 'Managers/bmc/EthernetInterfaces/' |
| REDFISH_NW_PROTOCOL = 'Managers/bmc/NetworkProtocol' |
| REDFISH_NW_PROTOCOL_URI = REDFISH_BASE_URI + REDFISH_NW_PROTOCOL |
| REDFISH_ACCOUNTS_SERVICE = 'AccountService/' |
| REDFISH_ACCOUNTS_SERVICE_URI = REDFISH_BASE_URI + REDFISH_ACCOUNTS_SERVICE |
| REDFISH_ACCOUNTS = 'AccountService/Accounts/' |
| REDFISH_ACCOUNTS_URI = REDFISH_BASE_URI + REDFISH_ACCOUNTS |
| REDFISH_HTTPS_CERTIFICATE = 'Managers/bmc/NetworkProtocol/HTTPS/Certificates' |
| REDFISH_HTTPS_CERTIFICATE_URI = REDFISH_BASE_URI + REDFISH_HTTPS_CERTIFICATE |
| REDFISH_LDAP_CERTIFICATE = 'AccountService/LDAP/Certificates' |
| REDFISH_LDAP_CERTIFICATE_URI = REDFISH_BASE_URI + REDFISH_LDAP_CERTIFICATE |
| REDFISH_CA_CERTIFICATE = 'Managers/bmc/Truststore/Certificates' |
| REDFISH_CA_CERTIFICATE_URI = REDFISH_BASE_URI + REDFISH_CA_CERTIFICATE |
| REDFISH_CHASSIS_URI = REDFISH_BASE_URI + 'Chassis/' |
| REDFISH_CHASSIS_THERMAL = 'chassis/Thermal/' |
| REDFISH_CHASSIS_THERMAL_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_THERMAL |
| REDFISH_CHASSIS_POWER = 'chassis/Power/' |
| REDFISH_CHASSIS_POWER_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_POWER |
| REDFISH_CHASSIS_SENSORS = 'chassis/Sensors' |
| REDFISH_CHASSIS_SENSORS_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_SENSORS |
| |
| # Boot options and URI variables. |
| POWER_ON = 'On' |
| POWER_GRACEFUL_OFF = "GracefulShutdown" |
| POWER_GRACEFUL_RESTART = "GracefulRestart" |
| POWER_FORCE_OFF = 'ForceOff' |
| |
| REDFISH_POWER = 'Systems/system/Actions/ComputerSystem.Reset' |
| REDFISH_POWER_URI = REDFISH_BASE_URI + REDFISH_POWER |
| |
| # rsyslog variables. |
| REMOTE_LOGGING_URI = OPENBMC_BASE_URI + 'logging/config/remote/' |
| |
| # Certificate variables. |
| SERVER_CERTIFICATE_URI = OPENBMC_BASE_URI + 'certs/server/https' |
| CLIENT_CERTIFICATE_URI = OPENBMC_BASE_URI + 'certs/client/ldap' |
| CA_CERTIFICATE_URI = OPENBMC_BASE_URI + 'certs/authority/ldap' |
| |
| # EventLog variables. |
| SYSTEM_BASE_URI = REDFISH_BASE_URI + 'Systems/system/' |
| EVENT_LOG_URI = SYSTEM_BASE_URI + 'LogServices/EventLog/' |
| DUMP_URI = SYSTEM_BASE_URI + 'LogServices/Dump/' |
| |
| BIOS_ATTR_URI = SYSTEM_BASE_URI + 'Bios' |
| BIOS_ATTR_SETTINGS_URI = BIOS_ATTR_URI + '/Settings' |
| |
| ''' |
| QEMU HTTPS variable: |
| |
| By default lib/resource.robot AUTH URI construct is as |
| ${AUTH_URI} https://${OPENBMC_HOST}${AUTH_SUFFIX} |
| ${AUTH_SUFFIX} is populated here by default EMPTY else |
| the port from the OS environment |
| ''' |
| |
| AUTH_SUFFIX = ":" + BuiltIn().get_variable_value("${HTTPS_PORT}", os.getenv('HTTPS_PORT', '443')) |
| |
| # Here contains a list of valid Properties bases on fru_type after a boot. |
| INVENTORY_ITEMS = { |
| "CPU": [ |
| "Custom Field 1", |
| "Custom Field 2", |
| "Custom Field 3", |
| "Custom Field 4", |
| "Custom Field 5", |
| "Custom Field 6", |
| "Custom Field 7", |
| "Custom Field 8", |
| "FRU File ID", |
| "Manufacturer", |
| "Name", |
| "Part Number", |
| "Serial Number", |
| "fault", |
| "fru_type", |
| "is_fru", |
| "present", |
| "version", |
| ], |
| |
| "DIMM": [ |
| "Asset Tag", |
| "Custom Field 1", |
| "Custom Field 2", |
| "Custom Field 3", |
| "Custom Field 4", |
| "Custom Field 5", |
| "Custom Field 6", |
| "Custom Field 7", |
| "Custom Field 8", |
| "FRU File ID", |
| "Manufacturer", |
| "Model Number", |
| "Name", |
| "Serial Number", |
| "Version", |
| "fault", |
| "fru_type", |
| "is_fru", |
| "present", |
| "version", |
| ], |
| "MEMORY_BUFFER": [ |
| "Custom Field 1", |
| "Custom Field 2", |
| "Custom Field 3", |
| "Custom Field 4", |
| "Custom Field 5", |
| "Custom Field 6", |
| "Custom Field 7", |
| "Custom Field 8", |
| "FRU File ID", |
| "Manufacturer", |
| "Name", |
| "Part Number", |
| "Serial Number", |
| "fault", |
| "fru_type", |
| "is_fru", |
| "present", |
| "version", |
| ], |
| "FAN": [ |
| "fault", |
| "fru_type", |
| "is_fru", |
| "present", |
| "version", |
| ], |
| "DAUGHTER_CARD": [ |
| "Custom Field 1", |
| "Custom Field 2", |
| "Custom Field 3", |
| "Custom Field 4", |
| "Custom Field 5", |
| "Custom Field 6", |
| "Custom Field 7", |
| "Custom Field 8", |
| "FRU File ID", |
| "Manufacturer", |
| "Name", |
| "Part Number", |
| "Serial Number", |
| "fault", |
| "fru_type", |
| "is_fru", |
| "present", |
| "version", |
| ], |
| "BMC": [ |
| "fault", |
| "fru_type", |
| "is_fru", |
| "manufacturer", |
| "present", |
| "version", |
| ], |
| "MAIN_PLANAR": [ |
| "Custom Field 1", |
| "Custom Field 2", |
| "Custom Field 3", |
| "Custom Field 4", |
| "Custom Field 5", |
| "Custom Field 6", |
| "Custom Field 7", |
| "Custom Field 8", |
| "Part Number", |
| "Serial Number", |
| "Type", |
| "fault", |
| "fru_type", |
| "is_fru", |
| "present", |
| "version", |
| ], |
| "SYSTEM": [ |
| "Custom Field 1", |
| "Custom Field 2", |
| "Custom Field 3", |
| "Custom Field 4", |
| "Custom Field 5", |
| "Custom Field 6", |
| "Custom Field 7", |
| "Custom Field 8", |
| "FRU File ID", |
| "Manufacturer", |
| "Model Number", |
| "Name", |
| "Serial Number", |
| "Version", |
| "fault", |
| "fru_type", |
| "is_fru", |
| "present", |
| "version", |
| ], |
| "CORE": [ |
| "fault", |
| "fru_type", |
| "is_fru", |
| "present", |
| "version", |
| ], |
| } |