| #!/usr/bin/python |
| |
| r""" |
| Contains PLDM-related constants. |
| """ |
| |
| PLDM_SUPPORTED_TYPES = ['base', 'platform', 'bios'] |
| |
| # PLDM types. |
| PLDM_TYPE_BASE = {'VALUE': '00', 'STRING': 'base'} |
| PLDM_TYPE_PLATFORM = {'VALUE': '02', 'STRING': 'platform'} |
| PLDM_TYPE_BIOS = {'VALUE': '03', 'STRING': 'bios'} |
| PLDM_TYPE_FRU = {'VALUE': '04', 'STRING': 'fru'} |
| PLDM_TYPE_OEM = {'VALUE': '3F', 'STRING': 'oem'} |
| |
| VERSION_BASE = {'VALUE': ['f1', 'f0', 'f0', '00'], 'STRING': '1.0.0'} |
| VERSION_PLATFORM = {'VALUE': ['f1', 'f0', 'f0', '00'], 'STRING': '1.1.1'} |
| VERSION_BIOS = {'VALUE': ['f1', 'f1', 'f1', '00'], 'STRING': '1.0.0'} |
| VERSION_FRU = {'VALUE': ['f1', 'f0', 'f0', '00'], 'STRING': '1.0.0'} |
| |
| # PLDM base related variables. |
| PLDM_BASE_CMD = { |
| 'GET_TID': '02', |
| 'GET_PLDM_VERSION': '03', |
| 'GET_PLDM_TYPES': '04', |
| 'GET_PLDM_COMMANDS': '05'} |
| |
| # Response lengths are inclusive of completion code. |
| GET_TID_RESP_BYTES = 2 |
| GET_PLDM_VERSION_RESP_BYTES = 10 |
| GET_PLDM_TYPES_RESP_BYTES = 9 |
| GET_PLDM_COMMANDS_RESP_BYTES = 33 |
| |
| # PLDM bios related variables. |
| PLDM_BIOS_CMD = { |
| 'GET_BIOS_TABLE': '01', |
| 'SET_BIOS_ATTRIBUTE_CURRENT_VALUE': '07', |
| 'GET_BIOS_ATTRIBUTE_CURRENT_VALUE_BY_HANDLE': '08', |
| 'GET_DATE_TIME': '0c'} |
| |
| PLDM_BIOS_TABLE_TYPES = { |
| 'STRING_TABLE': '00', |
| 'ATTRIBUTE_TABLE': '01', |
| 'ATTRIBUTE_VAL_TABLE': '02'} |
| |
| TRANSFER_OPERATION_FLAG = { |
| 'GETNEXTPART': '00', |
| 'GETFIRSTPART': '01'} |
| |
| TRANSFER_RESP_FLAG = { |
| 'PLDM_START': '01', |
| 'PLDM_MIDDLE': '02', |
| 'PLDM_END': '04', |
| 'PLDM_START_AND_END': '05'} |
| |
| # PLDM platform related variables. |
| PLDM_PLATFORM_CMD = { |
| 'SET_STATE_EFFECTER_STATES': '39', |
| 'GET_PDR': '51'} |
| |
| PLDM_PDR_TYPES = { |
| 'STATE_EFFECTER_PDR': '11'} |
| |
| # PLDM OEM related variables. |
| PLDM_FILEIO_CMD = { |
| 'GET_FILE_TABLE': '1', |
| 'READ_FILE': '4', |
| 'WRITE_FILE': '5', |
| 'READ_FILE_INTO_MEMORY': '6', |
| 'WRITE_FILE_FROM_MEMORY': '7'} |
| |
| PLDM_FILEIO_COMPLETION_CODES = { |
| 'INVALID_FILE_HANDLE': '80', |
| 'DATA_OUT_OF_RANGE': '81', |
| 'INVALID_READ_LENGTH': '82', |
| 'INVALID_WRITE_LENGTH': '83', |
| 'FILE_TABLE_UNAVAILABLE': '84', |
| 'INVALID_FILE_TABLE_TYPE': '85'} |
| |
| # PLDM FRU related variables. |
| PLDM_FRU_CMD = { |
| 'PLDM_GET_FRU_RECORD_TABLE_METADATA': '01', |
| 'PLDM_GET_FRU_RECORD_TABLE': '02'} |
| |
| # PLDM command format. |
| |
| ''' |
| e.g. : GetPLDMVersion usage |
| |
| pldmtool base GetPLDMVersion -t <pldm_type> |
| |
| pldm supported types |
| |
| base->0,platform->2,bios->3,fru->4 |
| |
| ''' |
| CMD_GETPLDMVERSION = 'base GetPLDMVersion -t %s' |
| |
| ''' |
| e.g. : PLDM raw command usage |
| |
| pldmtool raw -d 0x80 0x00 0x03 0x00 0x00 0x00 0x00 0x01 0x00 |
| |
| pldm raw -d 0x<header> 0x<pldm_type> 0x<pldm_cmd_type> 0x<payload_data> |
| ''' |
| |
| CMD_PLDMTOOL_RAW = 'raw -d 0x80' + '0x%s' + ' ' + '0x%s' |
| |
| |
| # PLDM command payload data. |
| |
| PAYLOAD_GetPLDMVersion = \ |
| ' 0x00 0x00 0x00 0x00 0x%s 0x%s' # %(TransferOperationFlag, PLDMType) |
| |
| |
| ''' |
| e.g. : SetDateTime usage |
| |
| pldmtool bios SetDateTime -d <YYYYMMDDHHMMSS> |
| |
| ''' |
| CMD_SETDATETIME = 'bios SetDateTime -d %s' |