| *** Settings *** |
| Documentation Energy scale base tests. |
| |
| |
| # Test Parameters: |
| # OPENBMC_HOST The BMC host name or IP address. |
| |
| |
| Resource ../lib/energy_scale_utils.robot |
| Resource ../lib/openbmc_ffdc.robot |
| Resource ../lib/utils.robot |
| Resource ../lib/logging_utils.robot |
| Library ../lib/logging_utils.py |
| |
| |
| Suite Setup Suite Setup Execution |
| Test Teardown Test Teardown Execution |
| |
| |
| *** Variables **** |
| |
| ${over_max_power} 4001 |
| ${max_power} 3050 |
| ${mid_power} 1950 |
| ${min_power} 600 |
| ${below_min_power} 499 |
| ${zero_power} 0 |
| # The power limits are documented in |
| # open-power/witherspoon-xml/master/witherspoon.xml. |
| |
| |
| *** Test Cases *** |
| |
| |
| Escale Base Test Inactive Monitoring |
| [Documentation] Run base power tests with DCMI power montoring off. |
| [Tags] Escale_Base_Test_Deactive_Monitoring |
| |
| Deactivate DCMI Power And Verify |
| Verify Power Limits |
| |
| |
| Escale Base Test Active Monitoring |
| [Documentation] Run base power tests with DCMI power monitoring on. |
| [Tags] Escale_Base_Test_Active_Monitoring |
| |
| Activate DCMI Power And Verify |
| Verify Power Limits |
| |
| |
| Escale Power Setting Via REST And Verify |
| [Documentation] Set power via REST and check using IPMI. |
| [Tags] Escale_Power_Setting_Via_REST_And_Verify |
| |
| # A convenient power level bewtwwn maximum and minimum. |
| ${test_power}= Set Variable 1700 |
| |
| # Set the power limit via REST. |
| Set DCMI Power Limit Via REST ${test_power} |
| |
| # Read the power limit using IPMI. |
| ${power_limit}= Get DCMI Power Limit |
| Should Be True ${power_limit} == ${test_power} |
| ... msg=Reading Power limit with IPMI failed after setting it with REST. |
| |
| |
| Escale Power Setting Via IPMI And Verify |
| [Documentation] Set power via IPMI then check via REST. |
| [Tags] Escale_Power_Setting_Via_IPMI_And_Verify |
| |
| # A convenient power level bewtwwn maximum and minimum. |
| ${test_power}= Set Variable 2200 |
| |
| # Set DCMI Power via IPMI. |
| Set DCMI Power Limit And Verify ${test_power} |
| |
| # Read the limit via REST. |
| ${power_limit}= Get DCMI Power Limit Via REST |
| Should Be True ${power_limit} == ${test_power} |
| ... msg=Reading power limit with REST failed after setting it with IPMI. |
| |
| |
| Escale Activation Test Via REST |
| [Documentation] Activate power monitoring via REST then check via IPMI. |
| [Tags] Escale_Activation_Test_Via_REST |
| |
| Activate DCMI Power Via REST |
| # Confirm activation state using IPMI. |
| Fail If DCMI Power Is Not Activated |
| |
| |
| Escale Dectivation Test Via REST |
| [Documentation] Deactivate power monitoring via REST and check via IPMI. |
| [Tags] Escale_Deactivation_Test_Via_REST |
| |
| Deactivate DCMI Power Via REST |
| # Confirm activation state using IPMI. |
| Fail If DCMI Power Is Not Deactivated |
| |
| |
| *** Keywords *** |
| |
| |
| Verify Power Limits |
| [Documentation] Set power levels and verify limits. |
| |
| Set DCMI Power Limit And Verify ${mid_power} |
| Test Power Limit ${min_power} ${below_min_power} |
| Test Power Limit ${min_power} ${zero_power} |
| Test Power Limit ${max_power} ${over_max_power} |
| |
| ${power_limit}= Get DCMI Power Limit |
| Should Be True ${power_limit} == ${max_power} |
| ... msg=Power at ${power_limit}. Power should be at ${max_power}. |
| |
| |
| Test Power Limit |
| [Documentation] Set power and check limit. |
| [Arguments] ${good_power} ${outside_bounds_power} |
| |
| # Description of argument(s): |
| # good_power A valid power setting, usually at a limit. |
| # outside_bounds_power A power level that is beyond the limit. |
| |
| Set DCMI Power Limit And Verify ${good_power} |
| |
| # Attempt set power limit out of range. |
| ${data}= Create Dictionary data=${outside_bounds_power} |
| Write Attribute ${CONTROL_HOST_URI}power_cap PowerCap data=${data} |
| |
| |
| Suite Setup Execution |
| [Documentation] Do test setup initialization. |
| |
| # Save the deactivation/activation setting. |
| ${cmd}= Catenate dcmi power get_limit | grep State |
| ${resp}= Run External IPMI Standard Command ${cmd} |
| # Response is either "Power Limit Active" or "No Active Power Limit". |
| ${initial_deactivation}= Get Count ${resp} No |
| # If deactivated: initial_deactivation = 1, 0 otherwise. |
| Set Suite Variable ${initial_deactivation} children=true |
| |
| # Save the power limit setting. |
| ${initial_power_setting}= Get DCMI Power Limit |
| Set Suite Variable ${initial_power_setting} children=true |
| |
| Delete All Error Logs |
| |
| |
| Test Teardown Execution |
| [Documentation] Do the post test teardown. |
| |
| FFDC On Test Case Fail |
| |
| # Restore the system's initial power limit setting. |
| Run Keyword If '${initial_power_setting}' != '${0}' |
| ... Set DCMI Power Limit And Verify ${initial_power_setting} |
| |
| # Restore the system's initial deactivation/activation setting. |
| Run Keyword If '${initial_deactivation}' == '${1}' |
| ... Deactivate DCMI Power And Verify ELSE Activate DCMI Power And Verify |
| |
| # Clean up any error logs before exiting. |
| Delete All Error Logs |