blob: 477be2ae79ea5a3f68a9e46705a1f2309b7b95df [file] [log] [blame]
*** Settings ***
Documentation Module to test IPMI chassis functionality.
Resource ../lib/ipmi_client.robot
Resource ../lib/openbmc_ffdc.robot
Resource ../lib/boot_utils.robot
Resource ../lib/bmc_dbus.robot
Library ../lib/ipmi_utils.py
Variables ../data/ipmi_raw_cmd_table.py
Suite Setup Redfish.Login
Suite Teardown Redfish.Logout
Test Teardown Test Teardown Execution
Force Tags IPMI_Chassis
*** Variables ***
# Timeout value in minutes. Default 3 minutes.
${IPMI_POWEROFF_WAIT_TIMEOUT} 3
${busctl_settings} xyz.openbmc_project.Settings
${chassis_capabilities_dbus_URL} /xyz/openbmc_project/Control/ChassisCapabilities
*** Test Cases ***
IPMI Chassis Status On
[Documentation] This test case verifies system power on status
... using IPMI Get Chassis status command.
[Tags] IPMI_Chassis_Status_On
Redfish Power On stack_mode=skip quiet=1
${resp}= Run External IPMI Standard Command chassis status
${power_status}= Get Lines Containing String ${resp} System Power
Should Contain ${power_status} on
IPMI Chassis Status Off
[Documentation] This test case verifies system power off status
... using IPMI Get Chassis status command.
[Tags] IPMI_Chassis_Status_Off
Redfish Power Off stack_mode=skip quiet=1
${resp}= Run External IPMI Standard Command chassis status
${power_status}= Get Lines Containing String ${resp} System Power
Should Contain ${power_status} off
Verify Host PowerOff Via IPMI
[Documentation] Verify host power off operation using external IPMI command.
[Tags] Verify_Host_PowerOff_Via_IPMI
IPMI Power Off
${ipmi_state}= Get Host State Via External IPMI
Valid Value ipmi_state ['off']
Verify Host PowerOn Via IPMI
[Documentation] Verify host power on operation using external IPMI command.
[Tags] Verify_Host_PowerOn_Via_IPMI
IPMI Power On
${ipmi_state}= Get Host State Via External IPMI
Valid Value ipmi_state ['on']
Verify Soft Shutdown
[Documentation] Verify host OS shutdown softly via IPMI command.
[Tags] Verify_Soft_Shutdown
Redfish Power On stack_mode=skip
Run External IPMI Standard Command chassis power soft
Wait Until Keyword Succeeds ${IPMI_POWEROFF_WAIT_TIMEOUT} min 10 sec Is Host Off Via IPMI
Verify Chassis Power Cycle And Check Chassis Status Via IPMI
[Documentation] Verify chassis power Cycle operation and check the Chassis
... Power Status using external IPMI command.
[Tags] Verify_Chassis_Power_Cycle_And_Check_Chassis_Status_Via_IPMI
# Chassis power cycle command via IPMI
IPMI Power Cycle
${ipmi_state}= Get Host State Via External IPMI
Valid Value ipmi_state ['on']
Verify Chassis Power Reset And Check Chassis Status Via IPMI
[Documentation] Verify chassis power Reset operation and check the Chassis
... Power Status using external IPMI command.
[Tags] Verify_Chassis_Power_Reset_And_Check_Chassis_Status_Via_IPMI
# Chassis power reset command via IPMI
IPMI Power Reset
${ipmi_state}= Get Host State Via External IPMI
Valid Value ipmi_state ['on']
Verify Chassis Power Policy
[Documentation] Verify setting chassis power policy via IPMI command.
[Tags] Verify_Chassis_Power_Policy
[Setup] Test Setup Execution
[Teardown] Run Keywords FFDC On Test Case Fail AND
... Run External IPMI Standard Command chassis policy ${initial_power_policy}
[Template] Set Chassis Power Policy Via IPMI And Verify
# power_policy
always-off
always-on
previous
Verify Chassis Status Via IPMI
[Documentation] Verify Chassis Status via IPMI command.
[Tags] Verify_Chassis_Status_Via_IPMI
[Setup] Test Setup Execution
[Teardown] Run Keywords FFDC On Test Case Fail AND
... Run External IPMI Standard Command chassis policy ${initial_power_policy}
[Template] Check Chassis Status Via IPMI
# power_policy
always-off
always-on
previous
Verify Get Chassis Capabilities
[Documentation] Verify get chassis capabilities IPMI cmd with valid data length and verify
... its response comparing with busctl command.
[Tags] Verify_Get_Chassis_Capabilities
[Teardown] FFDC On Test Case Fail
${ipmi_resp}= Run External IPMI Raw Command
... ${IPMI_RAW_CMD['Chassis Capabilities']['Get'][0]}
${ipmi_resp}= Split String ${ipmi_resp}
${busctl_cmd}= Catenate ${BUSCTL_INTROSPECT_COMMAND} ${busctl_settings}
... ${chassis_capabilities_dbus_URL}
${busctl_resp}= BMC Execute Command sh --login -c "${busctl_cmd}"
Verify Chassis Capabilities Response ${ipmi_resp[0]} ${busctl_resp[0]} CapabilitiesFlags
Verify Chassis Capabilities Response ${ipmi_resp[1]} ${busctl_resp[0]} FRUDeviceAddress
Verify Chassis Capabilities Response ${ipmi_resp[2]} ${busctl_resp[0]} SDRDeviceAddress
Verify Chassis Capabilities Response ${ipmi_resp[3]} ${busctl_resp[0]} SELDeviceAddress
Verify Chassis Capabilities Response ${ipmi_resp[4]} ${busctl_resp[0]} SMDeviceAddress
Verify Chassis Capabilities Response ${ipmi_resp[5]} ${busctl_resp[0]} BridgeDeviceAddress
Verify Get Chassis Capabilities With Invalid Data Length
[Documentation] Verify get chassis capabilities IPMI command with invalid data length
[Tags] Verify_Get_Chassis_Capabilities_With_Invalid_Data_Length
[Teardown] FFDC On Test Case Fail
Verify Invalid IPMI Command ${IPMI_RAW_CMD['Chassis Capabilities']['Get'][1]} 0xc7
*** Keywords ***
Set Chassis Power Policy Via IPMI And Verify
[Documentation] Set chasiss power policy via IPMI and verify.
[Arguments] ${power_policy}
# Description of argument(s):
# power_policy Chassis power policy to be set(e.g. "always-off", "always-on").
Run External IPMI Standard Command chassis policy ${power_policy}
${resp}= Get Chassis Status
Valid Value resp['power_restore_policy'] ['${power_policy}']
Check Chassis Status Via IPMI
[Documentation] Set Chassis Status via IPMI and verify and verify chassis status.
[Arguments] ${power_policy}
# Sets power policy according to requested policy
Set Chassis Power Policy Via IPMI And Verify ${power_policy}
# Gets chassis status via IPMI raw command and validate byte 1
${status}= Run External IPMI Raw Command ${IPMI_RAW_CMD['Chassis_status']['get'][0]}
${status}= Split String ${status}
${state}= Convert To Binary ${status[0]} base=16
${state}= Zfill Data ${state} 8
# Last bit corresponds whether Power is on
Should Be Equal As Strings ${state[-1]} 1
# bit 1-2 corresponds to power restore policy
${policy}= Set Variable ${state[1:3]}
# condition to verify each power policy
IF '${power_policy}' == 'always-off'
Should Be Equal As Strings ${policy} 00
ELSE IF '${power_policy}' == 'always-on'
Should Be Equal As Strings ${policy} 10
ELSE IF '${power_policy}' == 'previous'
Should Be Equal As Strings ${policy} 01
ELSE
Log Power Restore Policy is Unknown
Should Be Equal As Strings ${policy} 11
END
# Last Power Event - 4th bit should be 1b i.e, last ‘Power is on’ state was entered via IPMI command
${last_power_event}= Convert To Binary ${status[1]} base=16
${last_power_event}= Zfill Data ${last_power_event} 8
Should Be Equal As Strings ${last_power_event[3]} 1
Verify Chassis Capabilities Response
[Documentation] Will compare the ipmi response with thh busctl response for given property.
[Arguments] ${ipmi_response} ${busctl_response} ${property}
${ipmi_response}= Convert To Integer ${ipmi_response} 16
${busctl_value}= Get Regexp Matches ${busctl_response}
... \\.${property}\\s+property\\s+\\w\\s+(\\d+)\\s+ 1
Should Be Equal As Integers ${ipmi_response} ${busctl_value[0]}
Test Setup Execution
[Documentation] Do test setup tasks.
${chassis_status}= Get Chassis Status
Set Test Variable ${initial_power_policy} ${chassis_status['power_restore_policy']}
Test Teardown Execution
[Documentation] Do Test Teardown tasks.
${resp}= Run External IPMI Standard Command chassis status
${power_status}= Get Lines Containing String ${resp} System Power
@{powertolist}= Split String ${power_status} :
${status}= Get From List ${powertolist} 1
# Chassis Power ON if status is off
Run Keyword If '${status.strip()}' != 'on'
... Redfish Power On
FFDC On Test Case Fail