blob: 089fe220943f8e373bb6e2c97b59f0b188681ff0 [file] [log] [blame]
*** Settings ***
Documentation Module to test IPMI management controller ID functionality.
Resource ../lib/ipmi_client.robot
Resource ../lib/openbmc_ffdc.robot
Variables ../data/ipmi_raw_cmd_table.py
Test Teardown FFDC On Test Case Fail
*** Variables ***
${new_mc_id}= HOST
*** Test Cases ***
Verify Get And Set Management Controller ID String
[Documentation] Verify get and set management controller ID string.
[Tags] Verify_Get_And_Set_Management_Controller_ID_String
# Get the value of the managemment controller ID string.
# Example:
# Get Management Controller Identifier String: witherspoon
${cmd_output}= Run IPMI Standard Command dcmi get_mc_id_string
# Extract management controller ID from cmd_output.
${initial_mc_id}= Fetch From Right ${cmd_output} :${SPACE}
# Set the management controller ID string to other value.
# Example:
# Set Management Controller Identifier String Command: HOST
Set Management Controller ID String ${new_mc_id}
# Get the management controller ID and verify.
Get Management Controller ID String And Verify ${new_mc_id}
# Set the value back to the initial value and verify.
Set Management Controller ID String ${initial_mc_id}
# Get the management controller ID and verify.
Get Management Controller ID String And Verify ${initial_mc_id}
Test Management Controller ID String Status via IPMI
[Documentation] Test management controller ID string status via IPMI.
[Tags] Test_Management_Controller_ID_String_Status_via_IPMI
# Disable management controller ID string status via IPMI and verify.
Run IPMI Standard Command dcmi set_conf_param dhcp_config 0x00
Verify Management Controller ID String Status disable
# Enable management controller ID string status via IPMI and verify.
Run IPMI Standard Command dcmi set_conf_param dhcp_config 0x01
Verify Management Controller ID String Status enable
Test Management Controller ID String Status via Raw IPMI
[Documentation] Test management controller ID string status via IPMI.
[Tags] Test_Management_Controller_ID_String_Status_via_Raw_IPMI
# Disable management controller ID string status via raw IPMI and verify.
Run IPMI Standard Command raw ${IPMI_RAW_CMD['conf_param']['Disabled'][0]}
Verify Management Controller ID String Status disable
# Enable management controller ID string status via raw IPMI and verify.
Run IPMI Standard Command raw ${IPMI_RAW_CMD['conf_param']['Enabled'][0]}
Verify Management Controller ID String Status enable
*** Keywords ***
Set Management Controller ID String
[Documentation] Set the management controller ID string.
[Arguments] ${string}
# Description of argument(s):
# string Management Controller ID String to be set
${set_mc_id_string}= Run IPMI Standard Command
... dcmi set_mc_id_string ${string}
Get Management Controller ID String And Verify
[Documentation] Get the management controller ID string.
[Arguments] ${string}
# Description of argument(s):
# string Management Controller ID string
${get_mc_id}= Run IPMI Standard Command dcmi get_mc_id_string
Should Contain ${get_mc_id} ${string}
... msg=Command failed: get_mc_id.
Verify Management Controller ID String Status
[Documentation] Verify management controller ID string status via IPMI.
[Arguments] ${status}
# Example of dcmi get_conf_param command output:
# DHCP Discovery method :
# Management Controller ID String is disabled
# Vendor class identifier DCMI IANA and Vendor class-specific Informationa are disabled
# Initial timeout interval : 4 seconds
# Server contact timeout interval : 120 seconds
# Server contact retry interval : 64 seconds
${resp}= Run IPMI Standard Command dcmi get_conf_param
${resp}= Get Lines Containing String ${resp}
... Management Controller ID String case_insensitive=True
Should Contain ${resp} ${status}
... msg=Management controller ID string is not ${status}