${new_mc_id}= HOST
${allowed_temp_diff}= ${1}
*** Test Cases ***
Set Asset Tag With Valid String Length
[Documentation] Set asset tag with valid string length and verify.
[Tags] Set_Asset_Tag_With_Valid_String_Length
# Allowed MAX characters length for asset tag name is 63.
${random_string}= Generate Random String 63
Run Keyword Run IPMI Standard Command dcmi set_asset_tag ${random_string}
${asset_tag}= Run Keyword Run IPMI Standard Command dcmi asset_tag
Should Contain ${asset_tag} ${random_string}
Set Asset Tag With Invalid String Length
[Documentation] Verify error while setting invalid asset tag via IPMI.
[Tags] Set_Asset_Tag_With_Invalid_String_Length
# Any string more than 63 character is invalid for asset tag.
${random_string}= Generate Random String 64
${resp}= Run Keyword And Expect Error * Run IPMI Standard Command
... dcmi set_asset_tag ${random_string}
Should Contain ${resp} Parameter out of range ignore_case=True
Set Asset Tag With Valid String Length Via REST
[Documentation] Set valid asset tag via REST and verify.
[Tags] Set_Asset_Tag_With_Valid_String_Length_Via_REST
${random_string}= Generate Random String 63
${args}= Create Dictionary data=${random_string}
Write Attribute /xyz/openbmc_project/inventory/system AssetTag
... data=${args}
${asset_tag}= Read Attribute /xyz/openbmc_project/inventory/system
... AssetTag
Should Be Equal As Strings ${asset_tag} ${random_string}
Verify Get And Set Management Controller ID String
[Documentation] Verify get and set management controller ID string.
[Tags] Verify_Get_And_Set_Management_Controller_ID_String
# Get the value of the managemment controller ID string.
# Example:
# Get Management Controller Identifier String: witherspoon
${cmd_output}= Run IPMI Standard Command dcmi get_mc_id_string
# Extract management controller ID from cmd_output.
${initial_mc_id}= Fetch From Right ${cmd_output} :${SPACE}
# Set the management controller ID string to other value.
# Example:
# Set Management Controller Identifier String Command: HOST
Set Management Controller ID String ${new_mc_id}
# Get the management controller ID and verify.
Get Management Controller ID String And Verify ${new_mc_id}
# Set the value back to the initial value and verify.
Set Management Controller ID String ${initial_mc_id}
# Get the management controller ID and verify.
Get Management Controller ID String And Verify ${initial_mc_id}
Verify Chassis Identify via IPMI
[Documentation] Verify "chassis identify" using IPMI command.
[Tags] Verify_Chassis_Identify_via_IPMI
# Set to default "chassis identify" and verify that LED blinks for 15s.
Run IPMI Standard Command chassis identify
Verify Identify LED State Blink
Sleep 15s
Verify Identify LED State Off
# Set "chassis identify" to 10s and verify that the LED blinks for 10s.
Run IPMI Standard Command chassis identify 10
Verify Identify LED State Blink
Sleep 10s
Verify Identify LED State Off
Verify Chassis Identify Off And Force Identify On via IPMI
[Documentation] Verify "chassis identify" off
... and "force identify on" via IPMI.
[Tags] Verify_Chassis_Identify_Off_And_Force_Identify_On_via_IPMI
# Set the LED to "Force Identify On".
Run IPMI Standard Command chassis identify force
Verify Identify LED State Blink
# Set "chassis identify" to 0 and verify that the LED turns off.
Run IPMI Standard Command chassis identify 0
Verify Identify LED State Off
Test Watchdog Reset Via IPMI And Verify Using REST
[Documentation] Test watchdog reset via IPMI and verify using REST.
[Tags] Test_Watchdog_Reset_Via_IPMI_And_Verify_Using_REST
Initiate Host Boot
Set Watchdog Enabled Using REST ${1}
Watchdog Object Should Exist
# Resetting the watchdog via IPMI.
Run IPMI Standard Command mc watchdog reset
# Verify the watchdog is reset using REST after an interval of 1000ms.
Sleep 1000ms
${watchdog_time_left}=
... Read Attribute ${HOST_WATCHDOG_URI} TimeRemaining
Should Be True
... ${watchdog_time_left}<${1200000} and ${watchdog_time_left}>${2000}
... msg=Watchdog timer didn't reset.
Test Watchdog Off Via IPMI And Verify Using REST
[Documentation] Test watchdog off via IPMI and verify using REST.
[Tags] Test_Watchdog_Off_Via_IPMI_And_Verify_Using_REST
Initiate Host Boot
Set Watchdog Enabled Using REST ${1}
Watchdog Object Should Exist
# Turn off the watchdog via IPMI.
Run IPMI Standard Command mc watchdog off
# Verify the watchdog is off using REST
${watchdog_state}= Read Attribute ${HOST_WATCHDOG_URI} Enabled
Should Be Equal ${watchdog_state} ${0}
... msg=msg=Verification failed for watchdog off check.
Test Ambient Temperature Via IPMI
[Documentation] Test ambient temperature via IPMI and verify using REST.
[Tags] Test_Ambient_Temperature_Via_IPMI
# Entity ID Entity Instance Temp. Readings
# Inlet air temperature(40h) 1 +19 C
# CPU temperature sensors(41h) 5 +51 C
# CPU temperature sensors(41h) 6 +50 C
# CPU temperature sensors(41h) 7 +50 C
# CPU temperature sensors(41h) 8 +50 C
# CPU temperature sensors(41h) 9 +50 C
# CPU temperature sensors(41h) 10 +48 C
# CPU temperature sensors(41h) 11 +49 C
# CPU temperature sensors(41h) 12 +47 C
# CPU temperature sensors(41h) 8 +50 C
# CPU temperature sensors(41h) 16 +51 C
# CPU temperature sensors(41h) 24 +50 C
# CPU temperature sensors(41h) 32 +43 C
# CPU temperature sensors(41h) 40 +43 C
# Baseboard temperature sensors(42h) 1 +35 C
${temp_reading}= Run IPMI Standard Command dcmi get_temp_reading -N 10
${ambient_temp_line}=
... Get Lines Containing String ${temp_reading}
... Inlet air temperature case-insensitive
${ambient_temp_ipmi}= Fetch From Right ${ambient_temp_line} +
${ambient_temp_ipmi}= Remove String ${ambient_temp_ipmi} ${SPACE}C
${ambient_temp_rest}= Read Attribute
... ${SENSORS_URI}temperature/ambient Value
# Example of ambient temperature via REST
# "CriticalAlarmHigh": 0,
# "CriticalAlarmLow": 0,
# "CriticalHigh": 35000,
# "CriticalLow": 0,
# "Scale": -3,
# "Unit": "xyz.openbmc_project.Sensor.Value.Unit.DegreesC",
# "Value": 21775,
# "WarningAlarmHigh": 0,
# "WarningAlarmLow": 0,
# "WarningHigh": 25000,
# "WarningLow": 0
# Get temperature value based on scale i.e. Value * (10 power Scale Value)
# e.g. from above case 21775 * (10 power -3) = 21775/1000
${ambient_temp_rest}= Evaluate ${ambient_temp_rest}/1000
${ipmi_rest_temp_diff}=
... Evaluate abs(${ambient_temp_rest} - ${ambient_temp_ipmi})
Should Be True ${ipmi_rest_temp_diff} <= ${allowed_temp_diff}
... msg=Ambient temperature above allowed threshold ${allowed_temp_diff}.
Verify Get DCMI Capabilities
[Documentation] Verify get DCMI capabilities command output.
[Tags] Verify_Get_DCMI_Capabilities
${cmd_output}= Run IPMI Standard Command dcmi discover
@{supported_capabilities}= Create List
# Supported DCMI capabilities:
... Mandatory platform capabilties
... Optional platform capabilties
... Power management available
... Managebility access capabilties
... In-band KCS channel available
# Mandatory platform attributes:
... 200 SEL entries
... SEL automatic rollover is enabled
# Optional Platform Attributes:
... Slave address of device: 0h (8bits)(Satellite/External controller)
... Channel number is 0h (Primary BMC)
... Device revision is 0
# Manageability Access Attributes:
... Primary LAN channel number: 1 is available
... Secondary LAN channel is not available for OOB
... No serial channel is available
:FOR ${capability} IN @{supported_capabilities}
\ Should Contain ${cmd_output} ${capability} ignore_case=True
... msg=Supported DCMI capabilities not present.
*** Keywords ***
Set Management Controller ID String
[Documentation] Set the management controller ID string.
[Arguments] ${string}
# Description of argument(s):
# string Management Controller ID String to be set
${set_mc_id_string}= Run IPMI Standard Command
... dcmi set_mc_id_string ${string}
Get Management Controller ID String And Verify
[Documentation] Get the management controller ID sting.
[Arguments] ${string}
# Description of argument(s):
# string Management Controller ID string
${get_mc_id}= Run IPMI Standard Command dcmi get_mc_id_string
Should Contain ${get_mc_id} ${string}
... msg=Command failed: get_mc_id.
Verify Identify LED State
[Documentation] Verify the identify LED state
... matches caller's expectations.
[Arguments] ${expected_state}
# Description of argument(s):
# expected_state The LED state expected by the caller ("Blink" or "Off").
${resp}= Read Attribute ${LED_PHYSICAL_URI}/front_id State
Should Be Equal ${resp} xyz.openbmc_project.Led.Physical.Action.${expected_state}
... msg=Unexpected LED state.
${resp}= Read Attribute ${LED_PHYSICAL_URI}/rear_id State
Should Be Equal ${resp} xyz.openbmc_project.Led.Physical.Action.${expected_state}
... msg=Unexpected LED state.
Set Watchdog Enabled Using REST
[Documentation] Set watchdog Enabled field using REST.
[Arguments] ${value}
# Description of argument(s):
# value Integer value (eg. "0-Disabled", "1-Enabled").
${value_dict}= Create Dictionary data=${value}
${resp}= OpenBMC Put Request ${HOST_WATCHDOG_URI}/attr/Enabled
... data=${value_dict}