blob: 88e90d0badddceab2b1546327a822243ab117cb9 [file] [log] [blame]
*** Settings ***
Documentation This suite is used for testing eventlog association.
Resource ../lib/rest_client.robot
Resource ../lib/utils.robot
Resource ../lib/connection_client.robot
Library Collections
Suite Setup Open Connection And Log In
Suite Teardown Close All Connections
*** Variables ***
${SYSTEM_SHUTDOWN_TIME} 1min
${WAIT_FOR_SERVICES_UP} 3min
${CREATE_ERROR_SINGLE_FRU} busctl call org.openbmc.records.events /org/openbmc/records/events org.openbmc.recordlog acceptHostMessage sssay "Error" "Testing failure" "/org/openbmc/inventory/system/chassis/motherboard/dimm1" 1 1
${CREATE_ERROR_INVALID_FRU} busctl call org.openbmc.records.events /org/openbmc/records/events org.openbmc.recordlog acceptHostMessage sssay "Error" "Testing with invalid FRU" "abc" 1 1
${CREATE_ERROR_NO_FRU} busctl call org.openbmc.records.events /org/openbmc/records/events org.openbmc.recordlog acceptHostMessage sssay "Error" "Testing with no fru" "" 1 1
${CREATE_ERROR_VIRTUAL_SENSOR} busctl call org.openbmc.records.events /org/openbmc/records/events org.openbmc.recordlog acceptHostMessage sssay "Error" "Testing with a virtual sensor" "/org/openbmc/inventory/system/systemevent " 1 1
${DIMM1_URI} /org/openbmc/inventory/system/chassis/motherboard/dimm1
${DIMM2_URI} /org/openbmc/inventory/system/chassis/motherboard/dimm2
${DIMM3_URI} /org/openbmc/inventory/system/chassis/motherboard/dimm3
&{NIL} data=@{EMPTY}
*** Test Cases ***
Create error log on single FRU
[Documentation] ***GOOD PATH***
... Create an error log on single FRU and verify
... its association.\n
Clear all logs
${output}= Execute Command ${CREATE_ERROR_SINGLE_FRU}
${log_list} = Get EventList
${association_uri} = catenate SEPARATOR= ${log_list[0]} /fru
${association_content} = Read Attribute ${association_uri} endpoints
Should Contain ${association_content} ${DIMM1_URI}
${dimm1_event} = Read Attribute ${DIMM1_URI}/event endpoints
Should Contain ${dimm1_event} ${log_list[0]}
Create error log on two FRU
[Documentation] ***GOOD PATH***
... Create an error log on two FRUs and verify
... its association.\n
${log_uri} = Create a test log
${association_uri} = catenate SEPARATOR= ${log_uri} /fru
${association_content} = Read Attribute ${association_uri} endpoints
Should Contain ${association_content} ${DIMM3_URI}
Should Contain ${association_content} ${DIMM2_URI}
${dimm3_event} = Read Attribute ${DIMM3_URI}/event endpoints
Should Contain ${dimm3_event} ${log_uri}
${dimm2_event} = Read Attribute ${DIMM2_URI}/event endpoints
Should Contain ${dimm2_event} ${log_uri}
Create multiple error logs
[Documentation] ***GOOD PATH***
... Create multiple error logs and verify
... their association.\n
: FOR ${INDEX} IN RANGE 1 4
\ Log ${INDEX}
\ ${log_uri} = Create a test log
\ ${association_uri} = catenate SEPARATOR= ${log_uri} /fru
\ ${association_content} = Read Attribute ${association_uri} endpoints
\ Should Contain ${association_content} ${DIMM3_URI}
\ Should Contain ${association_content} ${DIMM2_URI}
\ ${dimm3_event} = Read Attribute ${DIMM3_URI}/event endpoints
\ Should Contain ${dimm3_event} ${log_uri}
\ ${dimm2_event} = Read Attribute ${DIMM2_URI}/event endpoints
\ Should Contain ${dimm2_event} ${log_uri}
Delete error log
[Documentation] ***BAD PATH***
... Delete an error log and verify that its
... association is also removed.\n
${log_uri1} = Create a test log
${association_uri1} = catenate SEPARATOR= ${log_uri1} /fru
${log_uri2} = Create a test log
${del_uri} = catenate SEPARATOR= ${log_uri1} /action/delete
${resp} = openbmc post request ${del_uri} data=${NIL}
should be equal as strings ${resp.status_code} ${HTTP_OK}
${resp} = openbmc get request ${association_uri1}
${jsondata} = to json ${resp.content}
Should Contain ${jsondata['message']} 404 Not Found
${dimm3_event} = Read Attribute ${DIMM3_URI}/event endpoints
Should Not Contain ${dimm3_event} ${log_uri1}
${dimm2_event} = Read Attribute ${DIMM2_URI}/event endpoints
Should Not Contain ${dimm2_event} ${log_uri1}
Association with invalid FRU
[Documentation] ***BAD PATH***
... Create an error log on invalid FRU and verify
... that its does not have any association.\n
Clear all logs
${output}= Execute Command ${CREATE_ERROR_INVALID_FRU}
${log_list} = Get EventList
${association_uri} = catenate SEPARATOR= ${log_list[0]} /fru
${resp} = openbmc get request ${association_uri}
${jsondata} = to json ${resp.content}
Should Contain ${jsondata['message']} 404 Not Found
Assocition with no FRU error event
[Documentation] ***BAD PATH***
... Create an error log on no FRU and verify
... that its does not have any association.\n
Clear all logs
${output}= Execute Command ${CREATE_ERROR_NO_FRU}
${log_list} = Get EventList
${association_uri} = catenate SEPARATOR= ${log_list[0]} /fru
${resp} = openbmc get request ${association_uri}
${jsondata} = to json ${resp.content}
Should Contain ${jsondata['message']} 404 Not Found
Association with virtual sensor
[Documentation] ***GOOD PATH***
... Create an error log on virtual sensor and
... verify its association.\n
Clear all logs
${output}= Execute Command ${CREATE_ERROR_VIRTUAL_SENSOR}
${log_list} = Get EventList
${association_uri} = catenate SEPARATOR= ${log_list[0]} /fru
${association_content} = Read Attribute ${association_uri} endpoints
Should Contain ${association_content} /org/openbmc/inventory/system/systemevent
Association unchanged after reboot
[Documentation] ***GOOD PATH***
... This test case is to verify that error log association
... does not change after open bmc reboot.\n
${pre_reboot_log_uri} = Create a test log
${association_uri} = catenate SEPARATOR= ${pre_reboot_log_uri} /fru
${pre_reboot_association_content} = Read Attribute ${association_uri} endpoints
${output}= Execute Command /sbin/reboot
Sleep ${SYSTEM_SHUTDOWN_TIME}
Wait For Host To Ping ${OPENBMC_HOST}
Sleep ${WAIT_FOR_SERVICES_UP}
${post_reboot_association_content} = Read Attribute ${association_uri} endpoints
Should Be Equal ${pre_reboot_association_content} ${pre_reboot_association_content}
${post_reboot_dimm3_event} = Read Attribute ${DIMM3_URI}/event endpoints
Should Contain ${post_reboot_dimm3_event} ${pre_reboot_log_uri}
${post_reboot_dimm2_event} = Read Attribute ${DIMM2_URI}/event endpoints
Should Contain ${post_reboot_dimm2_event} ${pre_reboot_log_uri}
*** Keywords ***
Get EventList
${resp} = openbmc get request /org/openbmc/records/events/
should be equal as strings ${resp.status_code} ${HTTP_OK}
${jsondata} = to json ${resp.content}
[return] ${jsondata['data']}
Create a test log
[arguments]
${data} = create dictionary data=@{EMPTY}
${resp} = openbmc post request /org/openbmc/records/events/action/acceptTestMessage data=${data}
should be equal as strings ${resp.status_code} ${HTTP_OK}
${json} = to json ${resp.content}
${LOGID} = convert to integer ${json['data']}
${uri}= catenate SEPARATOR= /org/openbmc/records/events/ ${LOGID}
[return] ${uri}
Clear all logs
${resp} = openbmc post request /org/openbmc/records/events/action/clear data=${NIL}
should be equal as strings ${resp.status_code} ${HTTP_OK}
${resp} = openbmc get request /org/openbmc/records/events/
${json} = to json ${resp.content}
Should Be Empty ${json['data']}